The present paper aims to evaluate the performance of a solar district cooling system in typical Middle East climate conditions. A centralized cooling station is supposed to distribute chilled water for a residential compound through a piping network. Two different solar cooling technologies are compared: two-stage lithium-bromide absorption chiller (2sABS) driven by Parabolic Trough Collectors (PTCs) vs. single-stage lithium-bromide absorption chiller (1sABS) fed by Evacuated Tube Collectors (ETCs). A computer code has been developed in Trnsys® (the transient simulation software developed by the University of Wisconsin) to simulate on hourly basis the annual operation of the solar cooling system, including building thermal load calculation, thermal losses in pipes and control strategy of the energy storage. A solar fraction of 70% was considered to size the solar field aperture area and the chiller capacity, within a multi-variable optimization process. An auxiliary compression chiller is supposed to cover the peak loads and to be used as backup unit. The two different solar cooling plants exhibit strongly different performance. For each plant configuration, the model determined the optimal size of every component leading to the primary cost minimization. The solar district cooling configuration based on 2sABS and PTCs shows higher performance at Riyadh (KSA) climate conditions and the overall cost is 30% lower than the one of the single-stage absorption chiller plant.

(2018). Performance Prediction of a Solar District Cooling System in Riyadh, Saudi Arabia - A Case Study [journal article - articolo]. In ENERGY CONVERSION AND MANAGEMENT. Retrieved from http://hdl.handle.net/10446/131581

Performance Prediction of a Solar District Cooling System in Riyadh, Saudi Arabia - A Case Study

Franchini, Giuseppe;BRUMANA, Giovanni;Perdichizzi, Antonio
2018-01-01

Abstract

The present paper aims to evaluate the performance of a solar district cooling system in typical Middle East climate conditions. A centralized cooling station is supposed to distribute chilled water for a residential compound through a piping network. Two different solar cooling technologies are compared: two-stage lithium-bromide absorption chiller (2sABS) driven by Parabolic Trough Collectors (PTCs) vs. single-stage lithium-bromide absorption chiller (1sABS) fed by Evacuated Tube Collectors (ETCs). A computer code has been developed in Trnsys® (the transient simulation software developed by the University of Wisconsin) to simulate on hourly basis the annual operation of the solar cooling system, including building thermal load calculation, thermal losses in pipes and control strategy of the energy storage. A solar fraction of 70% was considered to size the solar field aperture area and the chiller capacity, within a multi-variable optimization process. An auxiliary compression chiller is supposed to cover the peak loads and to be used as backup unit. The two different solar cooling plants exhibit strongly different performance. For each plant configuration, the model determined the optimal size of every component leading to the primary cost minimization. The solar district cooling configuration based on 2sABS and PTCs shows higher performance at Riyadh (KSA) climate conditions and the overall cost is 30% lower than the one of the single-stage absorption chiller plant.
articolo
2018
Franchini, Giuseppe; Brumana, Giovanni; Perdichizzi, Antonio Giovanni
(2018). Performance Prediction of a Solar District Cooling System in Riyadh, Saudi Arabia - A Case Study [journal article - articolo]. In ENERGY CONVERSION AND MANAGEMENT. Retrieved from http://hdl.handle.net/10446/131581
File allegato/i alla scheda:
File Dimensione del file Formato  
Performance prediction of a solar district cooling ENERGY CONVERSION AND MANAGEMENT 2018.pdf

Solo gestori di archivio

Versione: publisher's version - versione editoriale
Licenza: Licenza default Aisberg
Dimensione del file 4.64 MB
Formato Adobe PDF
4.64 MB Adobe PDF   Visualizza/Apri
ManuscriptPOST PRINT.pdf

Open Access dal 03/05/2020

Descrizione: link to the formal publication via its DOI 10.1016/j.enconman.2018.04.048
Versione: postprint - versione referata/accettata senza referaggio
Licenza: Creative commons
Dimensione del file 1.46 MB
Formato Adobe PDF
1.46 MB Adobe PDF Visualizza/Apri
Pubblicazioni consigliate

Aisberg ©2008 Servizi bibliotecari, Università degli studi di Bergamo | Terms of use/Condizioni di utilizzo

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/10446/131581
Citazioni
  • Scopus 34
  • ???jsp.display-item.citation.isi??? 28
social impact