The paper deals with the analysis of the new Combined Heat Cooling and Power (CHCP) Systems, considering a real installation in a plastic film industry. The major aim of the paper is the evaluation of the short-circuit currents in the main power center that supply the system. These values are really significant, because the presence of Distributed Generation (DG) systems connected to the distribution system determines an increase of the short-circuit currents that can impact the correct operation and selectivity of the protection system. A detailed model of the whole system has been implemented, using as input data the values coming from the real considered case of CHCP system. The test net, suitably realized, is then able to faithfully represents the considered system and it is used for carrying out many simulations. ©2009 IEEE.

(2009). Short Circuit Currents Evaluation in combined heat cooling and power (CHCP) systems [conference presentation - intervento a convegno]. Retrieved from http://hdl.handle.net/10446/23432

Short Circuit Currents Evaluation in combined heat cooling and power (CHCP) systems

ROSCIA, Mariacristina;
2009-01-01

Abstract

The paper deals with the analysis of the new Combined Heat Cooling and Power (CHCP) Systems, considering a real installation in a plastic film industry. The major aim of the paper is the evaluation of the short-circuit currents in the main power center that supply the system. These values are really significant, because the presence of Distributed Generation (DG) systems connected to the distribution system determines an increase of the short-circuit currents that can impact the correct operation and selectivity of the protection system. A detailed model of the whole system has been implemented, using as input data the values coming from the real considered case of CHCP system. The test net, suitably realized, is then able to faithfully represents the considered system and it is used for carrying out many simulations. ©2009 IEEE.
2009
Roscia, Mariacristina; Brenna, Morris; Foiadelli, Federica; Zaninelli, Dario
File allegato/i alla scheda:
File Dimensione del file Formato  
SHORT CIRCUIT CURRENT EVALUATION.pdf

Solo gestori di archivio

Versione: publisher's version - versione editoriale
Licenza: Licenza default Aisberg
Dimensione del file 195.3 kB
Formato Adobe PDF
195.3 kB Adobe PDF   Visualizza/Apri
Pubblicazioni consigliate

Aisberg ©2008 Servizi bibliotecari, Università degli studi di Bergamo | Terms of use/Condizioni di utilizzo

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/10446/23432
Citazioni
  • Scopus 0
  • ???jsp.display-item.citation.isi??? 0
social impact