In September 2008 the Slim5 collaboration submitted a low material budget silicon demonstrator to test with protons at the PS beam at CERN. The beam test setup was composed of a four double sided microstrip reference telescope and different detectors (DUTs) placed inside: a 4k-Pixel Matrix of Deep N Well MAPS, developed in a 130 nm CMOS Technology and a high resistivity double sided silicon detector, with short strips at 45 degree angle to the detectors edge, read out by the FSSR2 chip. All the systems were self-triggered and read out by a fast DAQ system. In the poster the beam test setup as the data acquisition and the trigger system are explained and the data acquisition performances are shown.

(2010). The high rate data acquisition system for the SLIM5 beam test [journal article - articolo]. In NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH. SECTION A, ACCELERATORS, SPECTROMETERS, DETECTORS AND ASSOCIATED EQUIPMENT. Retrieved from http://hdl.handle.net/10446/117792

The high rate data acquisition system for the SLIM5 beam test

Manghisoni, Massimo;Re, Valerio;Traversi, Gianluca;Gaioni, Luigi;
2010-01-01

Abstract

In September 2008 the Slim5 collaboration submitted a low material budget silicon demonstrator to test with protons at the PS beam at CERN. The beam test setup was composed of a four double sided microstrip reference telescope and different detectors (DUTs) placed inside: a 4k-Pixel Matrix of Deep N Well MAPS, developed in a 130 nm CMOS Technology and a high resistivity double sided silicon detector, with short strips at 45 degree angle to the detectors edge, read out by the FSSR2 chip. All the systems were self-triggered and read out by a fast DAQ system. In the poster the beam test setup as the data acquisition and the trigger system are explained and the data acquisition performances are shown.
journal article - articolo
2010
Fabbri, L.; Bruschi, M.; Di Sipio, R.; Giacobbe, B.; Gabrielli, A.; Giorgi, F.; Pellegrini, G.; Sbarra, C.; Semprini, N.; Spighi, R.; Valentinetti, S.; Villa, M.; Zoccoli, A.; Avanzini, C.; Batignani, G.; Bettarini, S.; Bosi, F.; Calderini, G.; Ceccanti, M.; Cenci, R.; Cervelli, A.; Crescioli, F.; Dell'Orso, M.; Forti, F.; Giannetti, P.; Giorgi, M.; Lusiani, A.; Gregucci, S.; Mammini, P.; Marchiori, G.; Massa, M.; Morsani, F.; Neri, N.; Paoloni, E.; Piendibene, M.; Profeti, A.; Rizzo, G.; Sartori, L.; Walsh, J.; Yurtsev, E.; Manghisoni, Massimo; Re, Valerio; Traversi, Gianluca; Andreoli, C.; Gaioni, Luigi; Pozzati, E.; Ratti, L.; Speziali, V.; Gamba, D.; Giraudo, G.; Mereu, P.; Dalla Betta, G. F.; Soncini, G.; Fontana, G.; Bomben, M.; Bosisio, L.; Cristaudo, P.; Giacomini, G.; Jugovaz, D.; Lanceri, L.; Rashevskaya, I.; Vitale, L.; Venier, G.
(2010). The high rate data acquisition system for the SLIM5 beam test [journal article - articolo]. In NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH. SECTION A, ACCELERATORS, SPECTROMETERS, DETECTORS AND ASSOCIATED EQUIPMENT. Retrieved from http://hdl.handle.net/10446/117792
File allegato/i alla scheda:
File Dimensione del file Formato  
12011018193100070.pdf

Solo gestori di archivio

Versione: publisher's version - versione editoriale
Licenza: Licenza default Aisberg
Dimensione del file 610.58 kB
Formato Adobe PDF
610.58 kB Adobe PDF   Visualizza/Apri
Pubblicazioni consigliate

Aisberg ©2008 Servizi bibliotecari, Università degli studi di Bergamo | Terms of use/Condizioni di utilizzo

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/10446/117792
Citazioni
  • Scopus 5
  • ???jsp.display-item.citation.isi??? 5
social impact