Although antiepileptic drug (AED) monitoring in saliva may have some clinical applicability, it has not yet come into routine use. The correlation between levetiracetam (LEV) saliva and serum concentrations also remains unclear. To confirm LEV saliva assay as a useful, noninvasive alternative to serum measurement, we investigated the possible correlation between saliva and serum LEV concentrations. Samples of saliva and blood were collected from 30 patients with epilepsy receiving chronic therapy with LEV as monotherapy or add-on therapy, and LEV concentrations were assayed in saliva and serum. Linear regression analyses showed a close correlation between saliva and serum LEV concentrations (r2 = 0.90; P < 0.001). LEV blood and saliva concentrations were linearly related to daily drug doses (r2 = 0.78 and 0.70; P < 0.01). When data were analyzed for subgroups (patients receiving LEV in monotherapy, as add-on therapy with enzyme-inducer AEDs, and as add-on therapy with noninducer or moderate-inducer AEDs), no significant difference was found between saliva and serum LEV concentrations among groups. These preliminary results indicate that LEV, like other AEDs, can be measured in saliva as an alternative to blood-based assays. Saliva LEV collection and assay is a valid noninvasive, more convenient alternative to serum measurement.

(2007). Saliva and serum levetiracetam concentrations in patients with epilepsy [journal article - articolo]. In THERAPEUTIC DRUG MONITORING. Retrieved from http://hdl.handle.net/10446/145504

Saliva and serum levetiracetam concentrations in patients with epilepsy

Romolo, Francesco Saverio;
2007-01-01

Abstract

Although antiepileptic drug (AED) monitoring in saliva may have some clinical applicability, it has not yet come into routine use. The correlation between levetiracetam (LEV) saliva and serum concentrations also remains unclear. To confirm LEV saliva assay as a useful, noninvasive alternative to serum measurement, we investigated the possible correlation between saliva and serum LEV concentrations. Samples of saliva and blood were collected from 30 patients with epilepsy receiving chronic therapy with LEV as monotherapy or add-on therapy, and LEV concentrations were assayed in saliva and serum. Linear regression analyses showed a close correlation between saliva and serum LEV concentrations (r2 = 0.90; P < 0.001). LEV blood and saliva concentrations were linearly related to daily drug doses (r2 = 0.78 and 0.70; P < 0.01). When data were analyzed for subgroups (patients receiving LEV in monotherapy, as add-on therapy with enzyme-inducer AEDs, and as add-on therapy with noninducer or moderate-inducer AEDs), no significant difference was found between saliva and serum LEV concentrations among groups. These preliminary results indicate that LEV, like other AEDs, can be measured in saliva as an alternative to blood-based assays. Saliva LEV collection and assay is a valid noninvasive, more convenient alternative to serum measurement.
articolo
2007
Mencarelli, Oriano; Li Voti, Pietro; Pro, Stefano; Romolo, Francesco Saverio; Rotolo, Maria; Pulitano, Patrizia; Accornero, Neri; Vanacore, Nicola
(2007). Saliva and serum levetiracetam concentrations in patients with epilepsy [journal article - articolo]. In THERAPEUTIC DRUG MONITORING. Retrieved from http://hdl.handle.net/10446/145504
File allegato/i alla scheda:
File Dimensione del file Formato  
2007TDM.pdf

Solo gestori di archivio

Versione: publisher's version - versione editoriale
Licenza: Licenza default Aisberg
Dimensione del file 186.4 kB
Formato Adobe PDF
186.4 kB Adobe PDF   Visualizza/Apri
Pubblicazioni consigliate

Aisberg ©2008 Servizi bibliotecari, Università degli studi di Bergamo | Terms of use/Condizioni di utilizzo

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/10446/145504
Citazioni
  • Scopus 28
  • ???jsp.display-item.citation.isi??? 26
social impact