The first lithium-drifted silicon (Si(Li)) detectors to satisfy the unique geometric, per- formance, and cost requirements of the General Antiparticle Spectrometer (GAPS) experiment have been produced by Shimadzu Corporation. The GAPS Si(Li) detectors will form the first large-area, relatively high-temperature Si(Li) detector system with sensitivity to X-rays to operate at high al- titude. These 10 cm-diameter, 2.5 mm-thick, 4- or 8-strip detectors provide the active area, X-ray absorption e ciency, energy resolution, and particle tracking capability necessary for the GAPS exotic-atom particle identification technique. In this paper, the detector performance is validated on the bases of X-ray energy resolution and reconstruction of cosmic minimum ionizing particle (MIP) signals. We use the established noise model for semiconductor detectors to distinguish sources of noise due to the detector from those due to signal processing electronics. We demonstrate that detectors with either 4 strips or 8 strips can provide the required 4 keV (FWHM) X-ray energy resolution at flight temperatures of 35 to 45°C, given the proper choice of signal processing electronics. Approximately 1000 8-strip detectors will be used for the first GAPS Antarctic balloon flight, scheduled for late 2021.

(2019). Large-area Si(Li) detectors for X-ray spectrometry and particle tracking in the GAPS experiment [journal article - articolo]. In JOURNAL OF INSTRUMENTATION. Retrieved from http://hdl.handle.net/10446/152596

Large-area Si(Li) detectors for X-ray spectrometry and particle tracking in the GAPS experiment

Manghisoni, M.;Re, V.;Riceputi, E.;
2019-01-01

Abstract

The first lithium-drifted silicon (Si(Li)) detectors to satisfy the unique geometric, per- formance, and cost requirements of the General Antiparticle Spectrometer (GAPS) experiment have been produced by Shimadzu Corporation. The GAPS Si(Li) detectors will form the first large-area, relatively high-temperature Si(Li) detector system with sensitivity to X-rays to operate at high al- titude. These 10 cm-diameter, 2.5 mm-thick, 4- or 8-strip detectors provide the active area, X-ray absorption e ciency, energy resolution, and particle tracking capability necessary for the GAPS exotic-atom particle identification technique. In this paper, the detector performance is validated on the bases of X-ray energy resolution and reconstruction of cosmic minimum ionizing particle (MIP) signals. We use the established noise model for semiconductor detectors to distinguish sources of noise due to the detector from those due to signal processing electronics. We demonstrate that detectors with either 4 strips or 8 strips can provide the required 4 keV (FWHM) X-ray energy resolution at flight temperatures of 35 to 45°C, given the proper choice of signal processing electronics. Approximately 1000 8-strip detectors will be used for the first GAPS Antarctic balloon flight, scheduled for late 2021.
articolo
2019
Rogers, F.; Xiao, M.; Perez, K. M.; Boggs, S.; Erjavec, T.; Fabris, L.; Fuke, H.; Hailey, C. J.; Kozai, M.; Lowell, A.; Madden, N.; Manghisoni, Massim...espandi
(2019). Large-area Si(Li) detectors for X-ray spectrometry and particle tracking in the GAPS experiment [journal article - articolo]. In JOURNAL OF INSTRUMENTATION. Retrieved from http://hdl.handle.net/10446/152596
File allegato/i alla scheda:
File Dimensione del file Formato  
Rogers_2019_J._Inst._14_P10009.pdf

Solo gestori di archivio

Versione: publisher's version - versione editoriale
Licenza: Licenza default Aisberg
Dimensione del file 5.07 MB
Formato Adobe PDF
5.07 MB Adobe PDF   Visualizza/Apri
Pubblicazioni consigliate

Aisberg ©2008 Servizi bibliotecari, Università degli studi di Bergamo | Terms of use/Condizioni di utilizzo

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/10446/152596
Citazioni
  • Scopus 22
  • ???jsp.display-item.citation.isi??? 17
social impact