In the present paper, the influence of inlet flow incidence on the aerodynamic and thermal performance of a film cooled linear nozzle vane cascade is fully assessed. Tests have been carried out on a solid and a cooled cascade. In the cooled cascade, coolant is ejected at the end wall through a slot located upstream of the leading edge plane. Moreover, a vane showerhead cooling system is also realized through four rows of cylindrical holes. The cascade was tested at a high inlet turbulence intensity level (Tu 1 =9%) and at a constant inlet Mach number of 0.12 and nominal cooling condition, varying the inlet flow angle in the range ±20 deg. The aero-thermal characterization of vane platform was obtained through five-hole probe and end wall adiabatic film cooling effectiveness measurements. Vane load distributions and surface flow visualizations supported the discussion of the results. A relevant negative impact of positive inlet flow incidence on the cooled cascade aerodynamic and thermal performance was detected. A negligible influence was instead observed at negative incidence, even at the lowest tested value of -20 deg.
(2019). Incidence effect on the aero- thermal performance of a film cooled nozzle vane cascade [journal article - articolo]. In JOURNAL OF TURBOMACHINERY. Retrieved from http://hdl.handle.net/10446/159342
Incidence effect on the aero- thermal performance of a film cooled nozzle vane cascade
Abdeh, H.;Barigozzi, G.;
2019-01-01
Abstract
In the present paper, the influence of inlet flow incidence on the aerodynamic and thermal performance of a film cooled linear nozzle vane cascade is fully assessed. Tests have been carried out on a solid and a cooled cascade. In the cooled cascade, coolant is ejected at the end wall through a slot located upstream of the leading edge plane. Moreover, a vane showerhead cooling system is also realized through four rows of cylindrical holes. The cascade was tested at a high inlet turbulence intensity level (Tu 1 =9%) and at a constant inlet Mach number of 0.12 and nominal cooling condition, varying the inlet flow angle in the range ±20 deg. The aero-thermal characterization of vane platform was obtained through five-hole probe and end wall adiabatic film cooling effectiveness measurements. Vane load distributions and surface flow visualizations supported the discussion of the results. A relevant negative impact of positive inlet flow incidence on the cooled cascade aerodynamic and thermal performance was detected. A negligible influence was instead observed at negative incidence, even at the lowest tested value of -20 deg.File | Dimensione del file | Formato | |
---|---|---|---|
turbo_141_05_051005.pdf
Solo gestori di archivio
Versione:
publisher's version - versione editoriale
Licenza:
Licenza default Aisberg
Dimensione del file
4.84 MB
Formato
Adobe PDF
|
4.84 MB | Adobe PDF | Visualizza/Apri |
Pubblicazioni consigliate
Aisberg ©2008 Servizi bibliotecari, Università degli studi di Bergamo | Terms of use/Condizioni di utilizzo