Purpose: Stereopsis is a fundamental skill in human vision and visual actions. There are many ways to test and quantify stereoacuity: traditional paper and new digital applications are both valid ways to test the stereoacuity. The aim of this study is to compare the results obtained using standard tests and the new Stereoacuity Test App developed by the University of Bergamo. Methods: A group of 497 children (272 males), aged between 6 and 11 years old, were tested using different tests for the quantification of stereopsis at near. These tests were TNO, Weiss EKW, and the new developed Stereoacuity Test App. Results: A one-way repeated measure ANOVA showed that the three tests give different thresholds of stereoacuity (p < 0.0001). Post hoc analyses with Bonferroni correction showed that all tests showed different thresholds (p < 0.0001). The lower threshold was obtained by Titmus Stereo Test followed by Stereoacuity App, Weiss MKW, and TNO. Conclusion: The stereoacuity based on global stereopsis showed that the better values were obtained in order by Stereoacuity Test App, TNO, and Weiss EKW. However, the clinical significance of their values is similar. The new digital test showed a greater compliance by the child, showing itself in tune with the digital characteristics of today’s children.

(2021). Evaluation of stereoacuity with a digital mobile application [journal article - articolo]. In GRAEFE'S ARCHIVE FOR CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY. Retrieved from http://hdl.handle.net/10446/181058

Evaluation of stereoacuity with a digital mobile application

Bonfanti, Silvia;Gargantini, Angelo;
2021-01-01

Abstract

Purpose: Stereopsis is a fundamental skill in human vision and visual actions. There are many ways to test and quantify stereoacuity: traditional paper and new digital applications are both valid ways to test the stereoacuity. The aim of this study is to compare the results obtained using standard tests and the new Stereoacuity Test App developed by the University of Bergamo. Methods: A group of 497 children (272 males), aged between 6 and 11 years old, were tested using different tests for the quantification of stereopsis at near. These tests were TNO, Weiss EKW, and the new developed Stereoacuity Test App. Results: A one-way repeated measure ANOVA showed that the three tests give different thresholds of stereoacuity (p < 0.0001). Post hoc analyses with Bonferroni correction showed that all tests showed different thresholds (p < 0.0001). The lower threshold was obtained by Titmus Stereo Test followed by Stereoacuity App, Weiss MKW, and TNO. Conclusion: The stereoacuity based on global stereopsis showed that the better values were obtained in order by Stereoacuity Test App, TNO, and Weiss EKW. However, the clinical significance of their values is similar. The new digital test showed a greater compliance by the child, showing itself in tune with the digital characteristics of today’s children.
articolo
2021
Bonfanti, Silvia; Gargantini, Angelo Michele; Esposito, Gabriele; Facchin, Alessio; Maffioletti, Marta; Maffioletti, Silvio
(2021). Evaluation of stereoacuity with a digital mobile application [journal article - articolo]. In GRAEFE'S ARCHIVE FOR CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY. Retrieved from http://hdl.handle.net/10446/181058
File allegato/i alla scheda:
File Dimensione del file Formato  
Bonfanti2021_Article_EvaluationOfStereoacuityWithAD.pdf

accesso aperto

Versione: publisher's version - versione editoriale
Licenza: Creative commons
Dimensione del file 742.59 kB
Formato Adobe PDF
742.59 kB Adobe PDF Visualizza/Apri
Pubblicazioni consigliate

Aisberg ©2008 Servizi bibliotecari, Università degli studi di Bergamo | Terms of use/Condizioni di utilizzo

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/10446/181058
Citazioni
  • Scopus 7
  • ???jsp.display-item.citation.isi??? 6
social impact