During the COVID-19 pandemic, many researchers all over the world have offered their time and competencies to face the heavy consequences of the disease. This is the case of a group of physicists, engineers, and physicians that around the middle of March 2020 started to develop a simplified mechanical lung ventilator, called MVM (Mechanical Ventilator Milano), to answer the high request of ventilators for Acute Respiratory Distress Syndrome (ARDS) in intensive care units. A prototype was ready in around one month. Since medical software malfunctions can lead to injuries or death of patients, before marketing MVM ventilators and distributing them in hospitals, software certification in accordance with the IEC 62304 standard was mandatory to guarantee system reliability. The team was then complemented by computer scientists specifically devoted to this task. The software reengineering process, which lasted around two months from the end of the prototype, brought to a strong re-implementation of the device software components, which involved all the stakeholders in a continuous integration setting. In this paper, we report the experience of the MVM control SW re-engineering necessary to show evidence that the SW adheres to the standards and to consequently obtain the certification. We share results and lessons learned from this social project, where more than 100 volunteer researchers worked towards software certification at the extreme of their strength to get a real device finished in a rush since strongly required to support physicians in treating COVID-19 patients.

(2021). Lessons Learned from the Development of a Mechanical Ventilator for COVID-19 . Retrieved from http://hdl.handle.net/10446/202108

Lessons Learned from the Development of a Mechanical Ventilator for COVID-19

Bombarda, Andrea;Bonfanti, Silvia;Gargantini, Angelo;
2021-01-01

Abstract

During the COVID-19 pandemic, many researchers all over the world have offered their time and competencies to face the heavy consequences of the disease. This is the case of a group of physicists, engineers, and physicians that around the middle of March 2020 started to develop a simplified mechanical lung ventilator, called MVM (Mechanical Ventilator Milano), to answer the high request of ventilators for Acute Respiratory Distress Syndrome (ARDS) in intensive care units. A prototype was ready in around one month. Since medical software malfunctions can lead to injuries or death of patients, before marketing MVM ventilators and distributing them in hospitals, software certification in accordance with the IEC 62304 standard was mandatory to guarantee system reliability. The team was then complemented by computer scientists specifically devoted to this task. The software reengineering process, which lasted around two months from the end of the prototype, brought to a strong re-implementation of the device software components, which involved all the stakeholders in a continuous integration setting. In this paper, we report the experience of the MVM control SW re-engineering necessary to show evidence that the SW adheres to the standards and to consequently obtain the certification. We share results and lessons learned from this social project, where more than 100 volunteer researchers worked towards software certification at the extreme of their strength to get a real device finished in a rush since strongly required to support physicians in treating COVID-19 patients.
2021
Bombarda, Andrea; Bonfanti, Silvia; Galbiati, Cristiano; Gargantini, Angelo Michele; Pelliccione, Patrizio; Riccobene, Elvinia; Wada, Masayuki
File allegato/i alla scheda:
File Dimensione del file Formato  
Lessons_Learned_from_the_Development_of_a_Mechanical_Ventilator_for_COVID-19.pdf

accesso aperto

Versione: publisher's version - versione editoriale
Licenza: Licenza default Aisberg
Dimensione del file 925.21 kB
Formato Adobe PDF
925.21 kB Adobe PDF Visualizza/Apri
Pubblicazioni consigliate

Aisberg ©2008 Servizi bibliotecari, Università degli studi di Bergamo | Terms of use/Condizioni di utilizzo

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/10446/202108
Citazioni
  • Scopus 3
  • ???jsp.display-item.citation.isi??? 0
social impact