Marker-less motion capture (MOCAP) systems based on consumer technology simplify the analysis of movements in several research fields such as industry, healthcare and sports. Even if the marker-less MOCAP systems have performances with precision and accuracy lower than the marker-based MOCAP solutions, their low cost and ease of use make them the most suitable tools for full-body movements analysis. The most interesting category is relative to the use of RGB-D devices. This research work aims to compare the performances of the last two generations of Kinect devices as marker-less MOCAP systems: Microsoft Kinect v2 and Azure devices. To conduct the tests, a list of specific movements is acquired and evaluated. This work measures the improvements of the Azure in tracking human body movements. The gathered results are presented and discussed by evaluating performances and limitations of both marker-less MOCAP systems. Conclusions and future developments are shown and discussed.

(2021). RGB-D Sensors as Marker-Less MOCAP Systems: A Comparison Between Microsoft Kinect V2 and the New Microsoft Kinect Azure . Retrieved from http://hdl.handle.net/10446/203287

RGB-D Sensors as Marker-Less MOCAP Systems: A Comparison Between Microsoft Kinect V2 and the New Microsoft Kinect Azure

Rosa, Benedetta;Colombo Zefinetti, Filippo;Vitali, Andrea;Regazzoni, Daniele
2021-01-01

Abstract

Marker-less motion capture (MOCAP) systems based on consumer technology simplify the analysis of movements in several research fields such as industry, healthcare and sports. Even if the marker-less MOCAP systems have performances with precision and accuracy lower than the marker-based MOCAP solutions, their low cost and ease of use make them the most suitable tools for full-body movements analysis. The most interesting category is relative to the use of RGB-D devices. This research work aims to compare the performances of the last two generations of Kinect devices as marker-less MOCAP systems: Microsoft Kinect v2 and Azure devices. To conduct the tests, a list of specific movements is acquired and evaluated. This work measures the improvements of the Azure in tracking human body movements. The gathered results are presented and discussed by evaluating performances and limitations of both marker-less MOCAP systems. Conclusions and future developments are shown and discussed.
2021
Rosa, Benedetta; COLOMBO ZEFINETTI, Filippo; Vitali, Andrea; Regazzoni, Daniele
File allegato/i alla scheda:
File Dimensione del file Formato  
Rosa2021_Chapter_RGB-DSensorsAsMarker-LessMOCAP.pdf

accesso aperto

Descrizione: © The Author(s), under exclusive license to Springer Nature Switzerland AG 2021
Versione: publisher's version - versione editoriale
Licenza: Licenza default Aisberg
Dimensione del file 1.05 MB
Formato Adobe PDF
1.05 MB Adobe PDF Visualizza/Apri
Pubblicazioni consigliate

Aisberg ©2008 Servizi bibliotecari, Università degli studi di Bergamo | Terms of use/Condizioni di utilizzo

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/10446/203287
Citazioni
  • Scopus 4
  • ???jsp.display-item.citation.isi??? ND
social impact