Since 1989 we performed stereotactic radiotherapy treatments of cerebral arterovenous malformations (AVM), estimating three-dimensional (3-D) localization and shape of target volumes by the Leksell stereotactic helmet on two orthogonal radiographic projections. Due to the limitations of this method, we developed a new technique for the localization of the target volume using digital subtraction angiography (DSA) and digital image processing. To achieve this result we first developed a method to correct nonlinear distortion of DSA images using spatial relocation of image pixels based on a calibration grid. We then developed an algorithm for localization of the target volume using two independent DSA projections. Target volume coordinates in the helmet system are calculated using two DSA acquisitions taken with a free angle (~90°), one in the AP and the other in the LL direction. The helmet can be freely positioned between the x-ray source and the image plane. The projections of eight reference points inserted in the helmet at a known location, are used to calculate the transformation matrix between the two coordinate systems. We performed numerical and experimental validation of the system. A hypothetical random error (up to 2 mm) on image coordinates of the reference points allowed to determine that the error in target localization was less than 0.2 mm. Using DSA images of target points with a known location within a phantom, the error between calculated and actual location was, on average, 0.30±0.13 mm (mean±SD), with a maximum error of 0.49 mm. The results of numerical and experimental validations show that the system we have developed allows fast and accurate localization of the center of the target volume and it is suitable for efficient guiding during stereotactic radiosurgery of AVM.

(2000). Localization of cerebral arterovenous malformations using digital angiography [journal article - articolo]. In MEDICAL PHYSICS. Retrieved from http://hdl.handle.net/10446/204419

Localization of cerebral arterovenous malformations using digital angiography

Remuzzi, Andrea
2000-01-01

Abstract

Since 1989 we performed stereotactic radiotherapy treatments of cerebral arterovenous malformations (AVM), estimating three-dimensional (3-D) localization and shape of target volumes by the Leksell stereotactic helmet on two orthogonal radiographic projections. Due to the limitations of this method, we developed a new technique for the localization of the target volume using digital subtraction angiography (DSA) and digital image processing. To achieve this result we first developed a method to correct nonlinear distortion of DSA images using spatial relocation of image pixels based on a calibration grid. We then developed an algorithm for localization of the target volume using two independent DSA projections. Target volume coordinates in the helmet system are calculated using two DSA acquisitions taken with a free angle (~90°), one in the AP and the other in the LL direction. The helmet can be freely positioned between the x-ray source and the image plane. The projections of eight reference points inserted in the helmet at a known location, are used to calculate the transformation matrix between the two coordinate systems. We performed numerical and experimental validation of the system. A hypothetical random error (up to 2 mm) on image coordinates of the reference points allowed to determine that the error in target localization was less than 0.2 mm. Using DSA images of target points with a known location within a phantom, the error between calculated and actual location was, on average, 0.30±0.13 mm (mean±SD), with a maximum error of 0.49 mm. The results of numerical and experimental validations show that the system we have developed allows fast and accurate localization of the center of the target volume and it is suitable for efficient guiding during stereotactic radiosurgery of AVM.
articolo
2000
Vitali, Angelo; Salmoiraghi, Paolo; Butti, Ivana; Pompei, Luciano; Sarti, Enrico; Caverni, Lionello; Petroboni, Eenrico; Merli, Rossella; Remuzzi, Andrea
(2000). Localization of cerebral arterovenous malformations using digital angiography [journal article - articolo]. In MEDICAL PHYSICS. Retrieved from http://hdl.handle.net/10446/204419
File allegato/i alla scheda:
File Dimensione del file Formato  
Medical Physics - 2000 - Vitali - Localization of cerebral arterovenous malformations using digital angiography.pdf

Solo gestori di archivio

Versione: publisher's version - versione editoriale
Licenza: Licenza default Aisberg
Dimensione del file 862.69 kB
Formato Adobe PDF
862.69 kB Adobe PDF   Visualizza/Apri
Pubblicazioni consigliate

Aisberg ©2008 Servizi bibliotecari, Università degli studi di Bergamo | Terms of use/Condizioni di utilizzo

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/10446/204419
Citazioni
  • Scopus 5
  • ???jsp.display-item.citation.isi??? 5
social impact