The present paper investigates the effect of endwall film cooling through discrete holes on the aerodynamic performance of a nozzle vane cascade. Experiments were performed on a simplified endwall cooling geometry operated at low Mach number (M=0.2), with holes located both upstream and downstream of the leading edge, varying the coolant to mainstream mass flow ratio. Secondary flow assessment with and without endwall film cooling was performed through flow visualizations and aerodynamic measurements. All these information allowed to draw a comprehensive picture of the complex aerodynamic flow field in the endwall region, enlightening the influence of endwall film cooling on the 3D flow field and secondary loss production. It was found that coolant injection strongly alter the secondary flow behaviour. A minimum loss has been found for injection rate MFR = 2.5%. The investigation of the effects of single row injection has shown that coolant injection upstream of the leading edge caused a lower secondary loss production, compared with those occurring in the rear part of the vane passage.

(2005). Aerodynamic measurements over a film cooled nozzle vane endwall . Retrieved from http://hdl.handle.net/10446/20616

Aerodynamic measurements over a film cooled nozzle vane endwall

Barigozzi, Giovanna;Benzoni, Giuseppe;Franchini, Giuseppe;Perdichizzi, Antonio Giovanni
2005-01-01

Abstract

The present paper investigates the effect of endwall film cooling through discrete holes on the aerodynamic performance of a nozzle vane cascade. Experiments were performed on a simplified endwall cooling geometry operated at low Mach number (M=0.2), with holes located both upstream and downstream of the leading edge, varying the coolant to mainstream mass flow ratio. Secondary flow assessment with and without endwall film cooling was performed through flow visualizations and aerodynamic measurements. All these information allowed to draw a comprehensive picture of the complex aerodynamic flow field in the endwall region, enlightening the influence of endwall film cooling on the 3D flow field and secondary loss production. It was found that coolant injection strongly alter the secondary flow behaviour. A minimum loss has been found for injection rate MFR = 2.5%. The investigation of the effects of single row injection has shown that coolant injection upstream of the leading edge caused a lower secondary loss production, compared with those occurring in the rear part of the vane passage.
2005
Barigozzi, Giovanna; Benzoni, Giuseppe; Franchini, Giuseppe; Perdichizzi, Antonio Giovanni
File allegato/i alla scheda:
File Dimensione del file Formato  
CFD Online - CFD Events Calendar - Event Record #521.pdf

Solo gestori di archivio

Versione: non applicabile
Licenza: Licenza default Aisberg
Dimensione del file 179.32 kB
Formato Adobe PDF
179.32 kB Adobe PDF   Visualizza/Apri
Pubblicazioni consigliate

Aisberg ©2008 Servizi bibliotecari, Università degli studi di Bergamo | Terms of use/Condizioni di utilizzo

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/10446/20616
Citazioni
  • Scopus 6
  • ???jsp.display-item.citation.isi??? ND
social impact