Classical synchronous generators have been used for decades in the field of power generation. The traditional manner of operation of these systems is the balanced, three phase configuration. However, recently there has been an interest in re-configuring consolidated, commercial, three phase generators to operate in single phase operation. A main driver for this phenomenon is the aim of manufacturers to extend their range of products for minimum development cost. Such an approach however brings a number of design challenges, especially in terms of the elevated damper cage currents and the negative sequence currents, when a 3-phase machine is 'forced' to operate in 1-phase. This paper therefore investigates and analyses these challenges. Considering a commercial, 3-phase, 400 kVA alternator. Detailed models, validated against experimental validation in 3-phase operation are first obtained. The machine is then re-configured to single phase operation. This paper proposes and shows how a suitable single phase loading can be found for 3-phase generators operating in single phase.
(2020). On single-phase operation of three-phase synchronous generators . Retrieved from http://hdl.handle.net/10446/224356
On single-phase operation of three-phase synchronous generators
Giangrande, Paolo;Serra, Giovanni
2020-01-01
Abstract
Classical synchronous generators have been used for decades in the field of power generation. The traditional manner of operation of these systems is the balanced, three phase configuration. However, recently there has been an interest in re-configuring consolidated, commercial, three phase generators to operate in single phase operation. A main driver for this phenomenon is the aim of manufacturers to extend their range of products for minimum development cost. Such an approach however brings a number of design challenges, especially in terms of the elevated damper cage currents and the negative sequence currents, when a 3-phase machine is 'forced' to operate in 1-phase. This paper therefore investigates and analyses these challenges. Considering a commercial, 3-phase, 400 kVA alternator. Detailed models, validated against experimental validation in 3-phase operation are first obtained. The machine is then re-configured to single phase operation. This paper proposes and shows how a suitable single phase loading can be found for 3-phase generators operating in single phase.File | Dimensione del file | Formato | |
---|---|---|---|
Published Version.pdf
Solo gestori di archivio
Versione:
publisher's version - versione editoriale
Licenza:
Licenza default Aisberg
Dimensione del file
1.43 MB
Formato
Adobe PDF
|
1.43 MB | Adobe PDF | Visualizza/Apri |
Pubblicazioni consigliate
Aisberg ©2008 Servizi bibliotecari, Università degli studi di Bergamo | Terms of use/Condizioni di utilizzo