Estimating the lifetime of enameled wires using the conventional/standard test method requires a significant amount of time that can endure up to thousands of testing hours, which could considerably delay the time-To-market of a new product. This paper presents a new approach that estimates the insulation lifetime of enameled wire, employed in electrical machines, using curve fitting models whose computation is rapid and accurate. Three curve fit models are adopted to predict the insulation resistance of double-coated enameled magnet wire samples, with respect to their aging time. The samples' mean time-To-failure is estimated, and performance of the models is apprised through a comparison against the conventional 'standard method' of lifetime estimation of the enameled wires. The best prediction accuracy is achieved by a logarithmic curve fit approach, which gives an error of 0.95% and 1.62% when its thermal index is compared with the conventional method and manufacturer claim respectively. The proposed approach provides a time-saving of 67% (83 days) when its computation time is compared with respect to the 'standard method' of lifetime estimation.
(2021). Lifetime Estimation of Enameled Wires under Accelerated Thermal Aging Using Curve Fitting Methods [journal article - articolo]. In IEEE ACCESS. Retrieved from http://hdl.handle.net/10446/224534
Lifetime Estimation of Enameled Wires under Accelerated Thermal Aging Using Curve Fitting Methods
Giangrande, Paolo;
2021-01-01
Abstract
Estimating the lifetime of enameled wires using the conventional/standard test method requires a significant amount of time that can endure up to thousands of testing hours, which could considerably delay the time-To-market of a new product. This paper presents a new approach that estimates the insulation lifetime of enameled wire, employed in electrical machines, using curve fitting models whose computation is rapid and accurate. Three curve fit models are adopted to predict the insulation resistance of double-coated enameled magnet wire samples, with respect to their aging time. The samples' mean time-To-failure is estimated, and performance of the models is apprised through a comparison against the conventional 'standard method' of lifetime estimation of the enameled wires. The best prediction accuracy is achieved by a logarithmic curve fit approach, which gives an error of 0.95% and 1.62% when its thermal index is compared with the conventional method and manufacturer claim respectively. The proposed approach provides a time-saving of 67% (83 days) when its computation time is compared with respect to the 'standard method' of lifetime estimation.File | Dimensione del file | Formato | |
---|---|---|---|
Published Vesion.pdf
Solo gestori di archivio
Versione:
publisher's version - versione editoriale
Licenza:
Licenza default Aisberg
Dimensione del file
1.83 MB
Formato
Adobe PDF
|
1.83 MB | Adobe PDF | Visualizza/Apri |
Pubblicazioni consigliate