Thermal modeling and temperature assessment of electrical machines often rely on the use of lumped-parameter thermal networks. A historic limitation of analytical thermal models is their need for an experimental fine-tuning, necessary for selecting the appropriate values of thermal conductivity and convection heat transfer coefficients. This evaluation procedure is commonly carried out at the design stage of a new machine, by assuming that its thermal behavior will remain unchanged throughout its whole lifetime. This paper demonstrates, through an in-depth experimental investigation, how the capability of heat extraction from a machine's hot spot towards the coolant can be strongly affected by the level of thermal aging of its insulation system. Based on the experimental findings, a decrement of the winding equivalent thermal conductivity is noted as the thermal aging accumulates, with a corresponding progressive increment in hot-spot temperature.
(2021). Influence of Insulation Thermal Aging on the Temperature Assessment in Electrical Machines [journal article - articolo]. In IEEE TRANSACTIONS ON ENERGY CONVERSION. Retrieved from http://hdl.handle.net/10446/224536
Influence of Insulation Thermal Aging on the Temperature Assessment in Electrical Machines
Giangrande, Paolo;
2021-01-01
Abstract
Thermal modeling and temperature assessment of electrical machines often rely on the use of lumped-parameter thermal networks. A historic limitation of analytical thermal models is their need for an experimental fine-tuning, necessary for selecting the appropriate values of thermal conductivity and convection heat transfer coefficients. This evaluation procedure is commonly carried out at the design stage of a new machine, by assuming that its thermal behavior will remain unchanged throughout its whole lifetime. This paper demonstrates, through an in-depth experimental investigation, how the capability of heat extraction from a machine's hot spot towards the coolant can be strongly affected by the level of thermal aging of its insulation system. Based on the experimental findings, a decrement of the winding equivalent thermal conductivity is noted as the thermal aging accumulates, with a corresponding progressive increment in hot-spot temperature.File | Dimensione del file | Formato | |
---|---|---|---|
Published Version.pdf
Solo gestori di archivio
Versione:
publisher's version - versione editoriale
Licenza:
Licenza default Aisberg
Dimensione del file
4.12 MB
Formato
Adobe PDF
|
4.12 MB | Adobe PDF | Visualizza/Apri |
Pubblicazioni consigliate
Aisberg ©2008 Servizi bibliotecari, Università degli studi di Bergamo | Terms of use/Condizioni di utilizzo