Electro-hydraulic elevators are widely used systems, especially in low level buildings, due to their very good ratio between power generation and dynamic response. Generally, the goal of an elevator system is just to reach the floor with a precision enough to be comfortable for the passengers, without the need to follow a specific law of motion; hence an open-loop control system could be enough. Otherwise such a kind of solution reduces the number of components, bringing down the costs of production. On the other hand a complete knowledge of the mechanical system’s behaviour is required. In this work we deal with the analysis of the behaviour of a commercial hydraulic elevator driven by an open loop control that monitors the downstream pressure of the proportional valve supplying the cylinder. At the end of the paper, a closed loop solution based on the pressure measurement and on the motion time is proposed.

(2009). Modeling Of a Hydraulic Elevator Driven by an Open-loop control [conference presentation - intervento a convegno]. Retrieved from http://hdl.handle.net/10446/23436

Modeling Of a Hydraulic Elevator Driven by an Open-loop control

Oldani, Alberto Claudio;Strada, Roberto
2009-01-01

Abstract

Electro-hydraulic elevators are widely used systems, especially in low level buildings, due to their very good ratio between power generation and dynamic response. Generally, the goal of an elevator system is just to reach the floor with a precision enough to be comfortable for the passengers, without the need to follow a specific law of motion; hence an open-loop control system could be enough. Otherwise such a kind of solution reduces the number of components, bringing down the costs of production. On the other hand a complete knowledge of the mechanical system’s behaviour is required. In this work we deal with the analysis of the behaviour of a commercial hydraulic elevator driven by an open loop control that monitors the downstream pressure of the proportional valve supplying the cylinder. At the end of the paper, a closed loop solution based on the pressure measurement and on the motion time is proposed.
2009
Oldani, Alberto Claudio; Strada, Roberto
File allegato/i alla scheda:
File Dimensione del file Formato  
IMECE2009-11219.pdf

Solo gestori di archivio

Versione: publisher's version - versione editoriale
Licenza: Licenza default Aisberg
Dimensione del file 601.6 kB
Formato Adobe PDF
601.6 kB Adobe PDF   Visualizza/Apri
Pubblicazioni consigliate

Aisberg ©2008 Servizi bibliotecari, Università degli studi di Bergamo | Terms of use/Condizioni di utilizzo

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/10446/23436
Citazioni
  • Scopus 0
  • ???jsp.display-item.citation.isi??? 0
social impact