Background: The emergency for the COVID-19 pandemic has led to greater use of home telemonitoring devices. The aim of this study was to assess the usability of continuous home-monitoring care with an oxygen saturation device on post-COVID-19 patients. Method: The system consists of a digital continuous pulse oximeter and a smartphone with an App, which were provided to patients. A survey composed of a standard Post-Study System Usability Questionnaire, and a satisfaction questionnaire was exploited to conduct a usability and feasibility analysis of the service. Results: A total of 29 patients (17.2% female) with a mean age of 65 ± 11.5 years were enrolled: 20 patients were smartphone users (69%) with a mean age of 60.2 ± 9.5 years, and 9 patients (31%) did not own a smartphone (mean age 76.8 ± 5.9). The monitoring period was 1 month: a total of 444 recordings were conducted, 15 recordings per patient averagely. In total, 82% of the recordings performed did not require any intervention, while 18% led to the production of a report and subsequent intervention by a nurse who verified, together with the specialist, the need to intervene (i.e. the patient accessed the clinic for medical control and/or modification of oxygen therapy). A total of 17 patients compiled a usability questionnaire. The service was perceived as useful and well-structured, although it often required caregiver support. Conclusions: Using continuous home-monitoring care with an oxygen saturation device seems feasible and useful for patients who could be followed at home avoiding going back to the hospital every time a trend oximetry is needed. Further improvements in connections, data flow processes, and simplifications, based on patients' feedback, are needed to scale up the service.
(2023). Usability of a continuous oxygen saturation device for home telemonitoring [journal article - articolo]. In DIGITAL HEALTH. Retrieved from https://hdl.handle.net/10446/251329
Usability of a continuous oxygen saturation device for home telemonitoring
Vitali, Andrea;Savoldelli, Anna;Rizzi, Caterina;
2023-08-14
Abstract
Background: The emergency for the COVID-19 pandemic has led to greater use of home telemonitoring devices. The aim of this study was to assess the usability of continuous home-monitoring care with an oxygen saturation device on post-COVID-19 patients. Method: The system consists of a digital continuous pulse oximeter and a smartphone with an App, which were provided to patients. A survey composed of a standard Post-Study System Usability Questionnaire, and a satisfaction questionnaire was exploited to conduct a usability and feasibility analysis of the service. Results: A total of 29 patients (17.2% female) with a mean age of 65 ± 11.5 years were enrolled: 20 patients were smartphone users (69%) with a mean age of 60.2 ± 9.5 years, and 9 patients (31%) did not own a smartphone (mean age 76.8 ± 5.9). The monitoring period was 1 month: a total of 444 recordings were conducted, 15 recordings per patient averagely. In total, 82% of the recordings performed did not require any intervention, while 18% led to the production of a report and subsequent intervention by a nurse who verified, together with the specialist, the need to intervene (i.e. the patient accessed the clinic for medical control and/or modification of oxygen therapy). A total of 17 patients compiled a usability questionnaire. The service was perceived as useful and well-structured, although it often required caregiver support. Conclusions: Using continuous home-monitoring care with an oxygen saturation device seems feasible and useful for patients who could be followed at home avoiding going back to the hospital every time a trend oximetry is needed. Further improvements in connections, data flow processes, and simplifications, based on patients' feedback, are needed to scale up the service.File | Dimensione del file | Formato | |
---|---|---|---|
Usability of a continuous oxygen saturation device for home telemonitoring.pdf
accesso aperto
Versione:
publisher's version - versione editoriale
Licenza:
Creative commons
Dimensione del file
1.92 MB
Formato
Adobe PDF
|
1.92 MB | Adobe PDF | Visualizza/Apri |
Pubblicazioni consigliate
Aisberg ©2008 Servizi bibliotecari, Università degli studi di Bergamo | Terms of use/Condizioni di utilizzo