In this paper the behaviour of RC buildings, whose structure includes frames, made of beams and columns, and shear walls, supporting lateral seismic loads acting on the entire building, is investigated. The columns, accordingly to NTC, chapter 7.2.3, are to be considered ìsecondary structural elementsî concerning the building response to seismic loads. A regular multi-storey building has been analyzed with typical dimensions and wall dispositions adopted in the current constructive practice. Pushover analyses are carried out using a code accounting for the effects of both geometrical non linearity and mechanical non linearity of materials.
Nella memoria si studia il comportamento di edifici prefabbricati la cui struttura, realizzata in calcestruzzo armato, comprende telai, costituiti da travi e pilastri, e pareti alle quali Ë affidata la resistenza alle azioni sismiche relative all'intero edificio. I pilastri, secondo quanto Ë previsto nelle NTC al capitolo 7.2.3, sono pertanto da considerarsi "elementi strutturali secondari" dal punto di vista della risposta dell'edificio alle azioni sismiche. E' stato analizzato un edificio regolare multipiano con dimensioni e disposizione delle pareti che possono ritenersi tipiche nella pratica costruttiva corrente. Le analisi pushover sono eseguite con l'ausilio di un codice di calcolo che ha messo in conto sia le non linearità geometriche sia le non linearità meccaniche dei materiali impiegati.
(2009). Alcune osservazioni sul comportamento di edifici prefabbricati a pareti in C.A. soggetti ad azione sismica [conference presentation - intervento a convegno]. Retrieved from https://hdl.handle.net/10446/256735
Alcune osservazioni sul comportamento di edifici prefabbricati a pareti in C.A. soggetti ad azione sismica
Riva, Paolo
2009-01-01
Abstract
In this paper the behaviour of RC buildings, whose structure includes frames, made of beams and columns, and shear walls, supporting lateral seismic loads acting on the entire building, is investigated. The columns, accordingly to NTC, chapter 7.2.3, are to be considered ìsecondary structural elementsî concerning the building response to seismic loads. A regular multi-storey building has been analyzed with typical dimensions and wall dispositions adopted in the current constructive practice. Pushover analyses are carried out using a code accounting for the effects of both geometrical non linearity and mechanical non linearity of materials.File | Dimensione del file | Formato | |
---|---|---|---|
Riva_Pisa-09-A-co-3-356.pdf
Solo gestori di archivio
Versione:
publisher's version - versione editoriale
Licenza:
Licenza default Aisberg
Dimensione del file
3.42 MB
Formato
Adobe PDF
|
3.42 MB | Adobe PDF | Visualizza/Apri |
Pubblicazioni consigliate
Aisberg ©2008 Servizi bibliotecari, Università degli studi di Bergamo | Terms of use/Condizioni di utilizzo