Background: Arteriovenous fistula (AVF) is the preferred vascular access (VA) for hemodialysis, but it is still affected by high non-maturation and early failure rates due to stenosis development. Increasing evidence suggests that the presence of turbulent-like flow may play a key role, therefore, to stabilize the flow in the venous segment, an external support device (VasQTM) has been designed. The aim of this study was to provide preliminary evidence of VasQ (TM) impact on AVF hemodynamics as compared to AVFs created with conventional surgery.Methods: In this pilot single-center prospective randomized study six patients were enrolled, three in the VasQ group and three in the control group. Contrast-free magnetic resonance imaging (MRI) scans were acquired at 3 days, 3 months and 1 year after AVF surgery and were used to generate 3D patient-specific models. Computational fluid dynamic (CFD) simulations were performed using pimpleFoam, imposing patient-specific flow waveforms derived from ultrasound (US) examinations at the inlet of the proximal and distal artery, and a traction-free condition at the venous outflow. Morphologic and hemodynamic changes occurring over time were compared between VasQ and control AVFs.Results: Our MRI protocol provided high-quality images suitable for reliable segmentation and reconstruction of patient-specific 3D models of AVFs at all three timepoints in four out of six patients. The VasQ (TM) device maintained the angle between the artery and the vein almost unchanged over time, with a more stable flow in the AVFs supported by the device. In contrast, one of the AVFs of the control group evolved to an extreme dilatation of the vein and highly disturbed flow, while the other developed a stenosis in the juxta-anastomotic region.Conclusions: This study demonstrated the feasibility of characterizing the morphological and hemodynamic changes occurring over time in AVFs created using the VasQ (TM) device and provided preliminary evidence of the potential hemodynamic benefits of its use.

(2024). Arteriovenous fistula creation with VasQTM device: A feasibility study to reveal hemodynamic implications [journal article - articolo]. In THE JOURNAL OF VASCULAR ACCESS. Retrieved from https://hdl.handle.net/10446/260774

Arteriovenous fistula creation with VasQTM device: A feasibility study to reveal hemodynamic implications

Poloni, Sofia;Remuzzi, Andrea
2024-01-01

Abstract

Background: Arteriovenous fistula (AVF) is the preferred vascular access (VA) for hemodialysis, but it is still affected by high non-maturation and early failure rates due to stenosis development. Increasing evidence suggests that the presence of turbulent-like flow may play a key role, therefore, to stabilize the flow in the venous segment, an external support device (VasQTM) has been designed. The aim of this study was to provide preliminary evidence of VasQ (TM) impact on AVF hemodynamics as compared to AVFs created with conventional surgery.Methods: In this pilot single-center prospective randomized study six patients were enrolled, three in the VasQ group and three in the control group. Contrast-free magnetic resonance imaging (MRI) scans were acquired at 3 days, 3 months and 1 year after AVF surgery and were used to generate 3D patient-specific models. Computational fluid dynamic (CFD) simulations were performed using pimpleFoam, imposing patient-specific flow waveforms derived from ultrasound (US) examinations at the inlet of the proximal and distal artery, and a traction-free condition at the venous outflow. Morphologic and hemodynamic changes occurring over time were compared between VasQ and control AVFs.Results: Our MRI protocol provided high-quality images suitable for reliable segmentation and reconstruction of patient-specific 3D models of AVFs at all three timepoints in four out of six patients. The VasQ (TM) device maintained the angle between the artery and the vein almost unchanged over time, with a more stable flow in the AVFs supported by the device. In contrast, one of the AVFs of the control group evolved to an extreme dilatation of the vein and highly disturbed flow, while the other developed a stenosis in the juxta-anastomotic region.Conclusions: This study demonstrated the feasibility of characterizing the morphological and hemodynamic changes occurring over time in AVFs created using the VasQ (TM) device and provided preliminary evidence of the potential hemodynamic benefits of its use.
articolo
2024
Bozzetto, Michela; Soliveri, Luca; Poloni, Sofia; Brambilla, Paolo; Curtò, Diego; Condemi, Giuseppina Carmela; Cefalì, Pietro; Spina, Irene; Villa, Al...espandi
(2024). Arteriovenous fistula creation with VasQTM device: A feasibility study to reveal hemodynamic implications [journal article - articolo]. In THE JOURNAL OF VASCULAR ACCESS. Retrieved from https://hdl.handle.net/10446/260774
File allegato/i alla scheda:
File Dimensione del file Formato  
bozzetto-et-al-2022-arteriovenous-fistula-creation-with-vasqtm-device-a-feasibility-study-to-reveal-hemodynamic.pdf

accesso aperto

Versione: publisher's version - versione editoriale
Licenza: Creative commons
Dimensione del file 2.43 MB
Formato Adobe PDF
2.43 MB Adobe PDF Visualizza/Apri
Pubblicazioni consigliate

Aisberg ©2008 Servizi bibliotecari, Università degli studi di Bergamo | Terms of use/Condizioni di utilizzo

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/10446/260774
Citazioni
  • Scopus 8
  • ???jsp.display-item.citation.isi??? 9
social impact