This paper presents damage assessment through Operational Modal Analysis (OMA) and Finite Element (FE) model updat- ing of the bell tower of the church of Castro in Bergamo, Italy. The tower is a 39 m high reinforced concrete structure with hollow cross-section and double-curved shape. The research was dictated by the need to identify the actual damage state of the structure, which was found through visual inspections. Piezoelectric accelerometers were used to record the ambient vibrations in subsequent test setups, using the roving technique for system identification. A detailed FE model was created with shell elements and calibrated to match the system identification results. A simplified beam model was then developed based on the modal analysis results of the detailed model. A sensitivity analysis was performed to identify the most influen- tial model parameters on the modal characteristics of the system. Subsequently, the optimal values of these parameters were determined by an optimisation procedure carried out using a typical global optimization algorithm. The updating results allowed assessment of the actual condition of the bell tower and its seismic vulnerability. Finally, a seismic strengthening solution was recommended.

(2024). Operational modal analysis, seismic vulnerability assessment and retrofit of a degraded RC bell tower [journal article - articolo]. In JOURNAL OF CIVIL STRUCTURAL HEALTH MONITORING. Retrieved from https://hdl.handle.net/10446/264576

Operational modal analysis, seismic vulnerability assessment and retrofit of a degraded RC bell tower

Castelli, Simone;Labo, Simone;Belleri, Andrea;
2024-01-01

Abstract

This paper presents damage assessment through Operational Modal Analysis (OMA) and Finite Element (FE) model updat- ing of the bell tower of the church of Castro in Bergamo, Italy. The tower is a 39 m high reinforced concrete structure with hollow cross-section and double-curved shape. The research was dictated by the need to identify the actual damage state of the structure, which was found through visual inspections. Piezoelectric accelerometers were used to record the ambient vibrations in subsequent test setups, using the roving technique for system identification. A detailed FE model was created with shell elements and calibrated to match the system identification results. A simplified beam model was then developed based on the modal analysis results of the detailed model. A sensitivity analysis was performed to identify the most influen- tial model parameters on the modal characteristics of the system. Subsequently, the optimal values of these parameters were determined by an optimisation procedure carried out using a typical global optimization algorithm. The updating results allowed assessment of the actual condition of the bell tower and its seismic vulnerability. Finally, a seismic strengthening solution was recommended.
articolo
2024
Castelli, Simone; Labo', Simone; Belleri, Andrea; Moaveni, Babak
(2024). Operational modal analysis, seismic vulnerability assessment and retrofit of a degraded RC bell tower [journal article - articolo]. In JOURNAL OF CIVIL STRUCTURAL HEALTH MONITORING. Retrieved from https://hdl.handle.net/10446/264576
File allegato/i alla scheda:
File Dimensione del file Formato  
IJ42 - Pub - OMA Seismic Castro.pdf

accesso aperto

Versione: publisher's version - versione editoriale
Licenza: Creative commons
Dimensione del file 6.66 MB
Formato Adobe PDF
6.66 MB Adobe PDF Visualizza/Apri
Pubblicazioni consigliate

Aisberg ©2008 Servizi bibliotecari, Università degli studi di Bergamo | Terms of use/Condizioni di utilizzo

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/10446/264576
Citazioni
  • Scopus 1
  • ???jsp.display-item.citation.isi??? 1
social impact