The paper investigates the suitability of grouted sleeve connections as column-to-foundation connections for precast concrete structures in seismic regions. Although grouted sleeves are commonly used, the typical advantages from this connection have not been fully addressed in the literature. Experiments on the cyclic behavior of column-tofoundation subassemblies compared the response of grouted sleeve connections with cast-in-place and pocket-foundation connections. The results demonstrate that grouted sleeves ensure a ductility and energy dissipation capacity similar to those of traditional connections. The confinement provided by the grouted sleeves inhibits buckling of the longitudinal reinforcement and increases the compressive strength of the grout. As a consequence, the damage associated with this kind of connection is localized to the column base, allowing easier postseismic column repair compared with traditional connections. The comparison of the experimental response of a grouted sleeve connection with partly unbonded reinforcement within the sleeves and the same specimen after retrofitting is also included.

Seismic performance and retrofit of precast concrete grouted sleeve connections

BELLERI, Andrea;RIVA, Paolo
2012-01-01

Abstract

The paper investigates the suitability of grouted sleeve connections as column-to-foundation connections for precast concrete structures in seismic regions. Although grouted sleeves are commonly used, the typical advantages from this connection have not been fully addressed in the literature. Experiments on the cyclic behavior of column-tofoundation subassemblies compared the response of grouted sleeve connections with cast-in-place and pocket-foundation connections. The results demonstrate that grouted sleeves ensure a ductility and energy dissipation capacity similar to those of traditional connections. The confinement provided by the grouted sleeves inhibits buckling of the longitudinal reinforcement and increases the compressive strength of the grout. As a consequence, the damage associated with this kind of connection is localized to the column base, allowing easier postseismic column repair compared with traditional connections. The comparison of the experimental response of a grouted sleeve connection with partly unbonded reinforcement within the sleeves and the same specimen after retrofitting is also included.
journal article - articolo
2012
Belleri, Andrea; Riva, Paolo
File allegato/i alla scheda:
File Dimensione del file Formato  
IJ-2012-01-PR.pdf

accesso aperto

Descrizione: publisher's version - versione dell'editore
Dimensione del file 1.33 MB
Formato Adobe PDF
1.33 MB Adobe PDF Visualizza/Apri
Pubblicazioni consigliate

Aisberg ©2008 Servizi bibliotecari, Università degli studi di Bergamo | Terms of use/Condizioni di utilizzo

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/10446/26522
Citazioni
  • Scopus 183
  • ???jsp.display-item.citation.isi??? 139
social impact