BACKGROUND: Few studies examined the validity of fitness tests based on perception scales. The field-based fitness tests batteries are composed by maximal tests and currently, a battery of submaximal tests does not exist. METHODS: Seventeen physically active male participants (age 40.5±10.7 years) performed the Multistage Fitness Test, the Crunch Test, the Push-Up Test and a Trunk Flexion Test with a submaximal protocol based on perceptual variables that were defined as non-validated submaximal. The mentioned tests were repeated three times to assess their reliability. The participants also performed four validated maximal tests comprising a velocity dependent ramp test on the treadmill, the Crunch Test, the Push-Up Test, and Sit-and-Reach Test. The submaximal tests were correlated to the maximal ones to assess their criterion validity. RESULTS: All the submaximal tests showed an ICC superior to 0.8 apart from the submaximal Crunch Test. The correlation between Maximal Treadmill Test and submaximal Multistage Fitness Test was 0.77. The correlation between Sit-and-Reach Test and submaximal Trunk Flexion Test was 0.71. Correlations equal to 0.66 and 0.60 were found between the maximal and submaximal Crunch Test and Push-Up Test respectively. CONCLUSIONS: The use of submaximal tests based on a fixed value of perception can represent a suitable tool to assess cardiorespiratory fitness and flexibility because of their correlation with the corresponding maximal evaluation tests and because of their reliability. On the contrary, muscular endurance capacity seems not to be assessable in the same manner.
(2018). Validity and reliability of submaximal fitness tests based on perceptual variables [journal article - articolo]. In JOURNAL OF SPORTS MEDICINE AND PHYSICAL FITNESS. Retrieved from https://hdl.handle.net/10446/274671
Validity and reliability of submaximal fitness tests based on perceptual variables
Crotti, Matteo;
2018-01-01
Abstract
BACKGROUND: Few studies examined the validity of fitness tests based on perception scales. The field-based fitness tests batteries are composed by maximal tests and currently, a battery of submaximal tests does not exist. METHODS: Seventeen physically active male participants (age 40.5±10.7 years) performed the Multistage Fitness Test, the Crunch Test, the Push-Up Test and a Trunk Flexion Test with a submaximal protocol based on perceptual variables that were defined as non-validated submaximal. The mentioned tests were repeated three times to assess their reliability. The participants also performed four validated maximal tests comprising a velocity dependent ramp test on the treadmill, the Crunch Test, the Push-Up Test, and Sit-and-Reach Test. The submaximal tests were correlated to the maximal ones to assess their criterion validity. RESULTS: All the submaximal tests showed an ICC superior to 0.8 apart from the submaximal Crunch Test. The correlation between Maximal Treadmill Test and submaximal Multistage Fitness Test was 0.77. The correlation between Sit-and-Reach Test and submaximal Trunk Flexion Test was 0.71. Correlations equal to 0.66 and 0.60 were found between the maximal and submaximal Crunch Test and Push-Up Test respectively. CONCLUSIONS: The use of submaximal tests based on a fixed value of perception can represent a suitable tool to assess cardiorespiratory fitness and flexibility because of their correlation with the corresponding maximal evaluation tests and because of their reliability. On the contrary, muscular endurance capacity seems not to be assessable in the same manner.File | Dimensione del file | Formato | |
---|---|---|---|
Submaximal Fitness assessment Paper (1).pdf
Solo gestori di archivio
Versione:
publisher's version - versione editoriale
Licenza:
Licenza default Aisberg
Dimensione del file
6.65 MB
Formato
Adobe PDF
|
6.65 MB | Adobe PDF | Visualizza/Apri |
Pubblicazioni consigliate
Aisberg ©2008 Servizi bibliotecari, Università degli studi di Bergamo | Terms of use/Condizioni di utilizzo