The first step in diagnosing a patient with cancer is the biopsy and the study of the tissue sample taken, suitably processed, is essential for a correct diagnosis. Tissue processors are machines that automatically perform the entire processing protocol, often relying on empirical timing related to chemical diffusions in the biological samples. The determination of the diffusion coefficient in porous materials, such as histological tissue, is still under study with multiple methods often resulting in inaccurate predictions and with few amounts of literature data for biological samples. The authors present an experimental technique, based on a multitude of X-ray radiographs acquired over time, where the intensity of the attenuation to the ionising beam is proportional to the concentration of the solvent that diffuses in the histological preparation. The paper so describes a proof-of-concept of a novel method to estimate the diffusion coefficient in a histological sample, based on the acquisition of time-dependent X-ray radiographs and the solution of an inverse diffusion problem.

(2024). A novel methodology for the diffusion coefficient determination in porous media by X-ray high-resolution radiographies [journal article - articolo]. In THE EUROPEAN PHYSICAL JOURNAL PLUS. Retrieved from https://hdl.handle.net/10446/278049

A novel methodology for the diffusion coefficient determination in porous media by X-ray high-resolution radiographies

Santini, Maurizio;Fest-Santini, Stephanie;Cossali, Gianpietro;Lupo, Carmelo
2024-01-01

Abstract

The first step in diagnosing a patient with cancer is the biopsy and the study of the tissue sample taken, suitably processed, is essential for a correct diagnosis. Tissue processors are machines that automatically perform the entire processing protocol, often relying on empirical timing related to chemical diffusions in the biological samples. The determination of the diffusion coefficient in porous materials, such as histological tissue, is still under study with multiple methods often resulting in inaccurate predictions and with few amounts of literature data for biological samples. The authors present an experimental technique, based on a multitude of X-ray radiographs acquired over time, where the intensity of the attenuation to the ionising beam is proportional to the concentration of the solvent that diffuses in the histological preparation. The paper so describes a proof-of-concept of a novel method to estimate the diffusion coefficient in a histological sample, based on the acquisition of time-dependent X-ray radiographs and the solution of an inverse diffusion problem.
articolo
2024
Santini, Maurizio; FEST SANTINI, Stephanie; Cossali, Gianpietro; Casatta, N.; Lupo, Carmelo
(2024). A novel methodology for the diffusion coefficient determination in porous media by X-ray high-resolution radiographies [journal article - articolo]. In THE EUROPEAN PHYSICAL JOURNAL PLUS. Retrieved from https://hdl.handle.net/10446/278049
File allegato/i alla scheda:
File Dimensione del file Formato  
A novel methodology for the diffusion coefficient determination in porous media by X-ray high-resolution radiographies.pdf

accesso aperto

Versione: publisher's version - versione editoriale
Licenza: Creative commons
Dimensione del file 665.08 kB
Formato Adobe PDF
665.08 kB Adobe PDF Visualizza/Apri
Pubblicazioni consigliate

Aisberg ©2008 Servizi bibliotecari, Università degli studi di Bergamo | Terms of use/Condizioni di utilizzo

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/10446/278049
Citazioni
  • Scopus 0
  • ???jsp.display-item.citation.isi??? 0
social impact