Attenzione: i dati modificati non sono ancora stati salvati. Per confermare inserimenti o cancellazioni di voci è necessario confermare con il tasto SALVA/INSERISCI in fondo alla pagina
We report measurements of the lifetimes of the Lambda(+)(c), Xi(+)(c) and Xi(0)(c) charm baryons using proton- proton collision data at center- of- mass energies of 7 and 8 TeV, corresponding to an integrated luminosity of 3.0 fb(-1), collected by the LHCb experiment. The charm baryons are reconstructed through the decays Lambda(+)(c) -> pK(-)pi(+),. Xi(+)(c) -> pK(-) pi(+) and Xi(0)(c) -> pK(-) K- pi(+), and originate from semimuonic decays of beauty baryons. The lifetimes are measured relative to that of the D+ meson, and are determined to be tau Lambda(+)(c) = 203.5 +/- 1.0 +/- 1.3 +/- 1.4 fs; tau Xi(+)(c) = 456.8 +/- 3.5 +/- 2.9 +/- 3.1 fs; tau Xi(0)(c) = 154.5 +/- 1.7 +/- 1.6 +/- 1.0 fs; where the uncertainties are statistical, systematic, and due to the uncertainty in the D+ lifetime. The measurements are approximately 3- 4 times more precise than the current world average values. The. +c and Xi(+)(c) lifetimes are in agreement with previous measurements; however, the Xi(0)(c) baryon lifetime is approximately 3.3 standard deviations larger than the world average value.
(2019). Precision measurement of the Λ+c , Ξ+c , and Ξ0c baryon lifetimes [journal article - articolo]. In PHYSICAL REVIEW D. Retrieved from https://hdl.handle.net/10446/283250
Precision measurement of the Λ+c , Ξ+c , and Ξ0c baryon lifetimes
We report measurements of the lifetimes of the Lambda(+)(c), Xi(+)(c) and Xi(0)(c) charm baryons using proton- proton collision data at center- of- mass energies of 7 and 8 TeV, corresponding to an integrated luminosity of 3.0 fb(-1), collected by the LHCb experiment. The charm baryons are reconstructed through the decays Lambda(+)(c) -> pK(-)pi(+),. Xi(+)(c) -> pK(-) pi(+) and Xi(0)(c) -> pK(-) K- pi(+), and originate from semimuonic decays of beauty baryons. The lifetimes are measured relative to that of the D+ meson, and are determined to be tau Lambda(+)(c) = 203.5 +/- 1.0 +/- 1.3 +/- 1.4 fs; tau Xi(+)(c) = 456.8 +/- 3.5 +/- 2.9 +/- 3.1 fs; tau Xi(0)(c) = 154.5 +/- 1.7 +/- 1.6 +/- 1.0 fs; where the uncertainties are statistical, systematic, and due to the uncertainty in the D+ lifetime. The measurements are approximately 3- 4 times more precise than the current world average values. The. +c and Xi(+)(c) lifetimes are in agreement with previous measurements; however, the Xi(0)(c) baryon lifetime is approximately 3.3 standard deviations larger than the world average value.
(2019). Precision measurement of the Λ+c , Ξ+c , and Ξ0c baryon lifetimes [journal article - articolo]. In PHYSICAL REVIEW D. Retrieved from https://hdl.handle.net/10446/283250
Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/10446/283250
Citazioni
37
24
social impact
Conferma cancellazione
Sei sicuro che questo prodotto debba essere cancellato?
simulazione ASN
Il report seguente simula gli indicatori relativi alla propria produzione scientifica in relazione alle soglie ASN 2023-2025 del proprio SC/SSD. Si ricorda che il superamento dei valori soglia (almeno 2 su 3) è requisito necessario ma non sufficiente al conseguimento dell'abilitazione. La simulazione si basa sui dati IRIS e sugli indicatori bibliometrici alla data indicata e non tiene conto di eventuali periodi di congedo obbligatorio, che in sede di domanda ASN danno diritto a incrementi percentuali dei valori. La simulazione può differire dall'esito di un’eventuale domanda ASN sia per errori di catalogazione e/o dati mancanti in IRIS, sia per la variabilità dei dati bibliometrici nel tempo. Si consideri che Anvur calcola i valori degli indicatori all'ultima data utile per la presentazione delle domande.
La presente simulazione è stata realizzata sulla base delle specifiche raccolte sul tavolo ER del Focus Group IRIS coordinato dall’Università di Modena e Reggio Emilia e delle regole riportate nel DM 589/2018 e allegata Tabella A. Cineca, l’Università di Modena e Reggio Emilia e il Focus Group IRIS non si assumono alcuna responsabilità in merito all’uso che il diretto interessato o terzi faranno della simulazione. Si specifica inoltre che la simulazione contiene calcoli effettuati con dati e algoritmi di pubblico dominio e deve quindi essere considerata come un mero ausilio al calcolo svolgibile manualmente o con strumenti equivalenti.