In July 2018 an optimization run for the proposed charm cross section measurement for SHiP was performed at the CERN SPS. A heavy, moving target instrumented with nuclear emulsion films followed by a silicon pixel tracker was installed in front of the Goliath magnet at the H4 proton beam-line. Behind the magnet, scintillating-fibre, drift-tube and RPC detectors were placed. The purpose of this run was to validate the measurement's feasibility, to develop the required analysis tools and fine-tune the detector layout. In this paper, we present the track reconstruction in the pixel tracker and the track matching with the moving emulsion detector. The pixel detector performed as expected and it is shown that, after proper alignment, a vertex matching rate of 87% is achieved.

(2022). Track reconstruction and matching between emulsion and silicon pixel detectors for the SHiP-charm experiment [journal article - articolo]. In JOURNAL OF INSTRUMENTATION. Retrieved from https://hdl.handle.net/10446/288161

Track reconstruction and matching between emulsion and silicon pixel detectors for the SHiP-charm experiment

Redi F;
2022-01-01

Abstract

In July 2018 an optimization run for the proposed charm cross section measurement for SHiP was performed at the CERN SPS. A heavy, moving target instrumented with nuclear emulsion films followed by a silicon pixel tracker was installed in front of the Goliath magnet at the H4 proton beam-line. Behind the magnet, scintillating-fibre, drift-tube and RPC detectors were placed. The purpose of this run was to validate the measurement's feasibility, to develop the required analysis tools and fine-tune the detector layout. In this paper, we present the track reconstruction in the pixel tracker and the track matching with the moving emulsion detector. The pixel detector performed as expected and it is shown that, after proper alignment, a vertex matching rate of 87% is achieved.
articolo
2022
Ahdida, C; Akmete, A; Albanese, R; Alt, J; Alexandrov, A; Anokhina, A; Aoki, S; Arduini, G; Atkin, E; Azorskiy, N; Back, Jj; Bagulya, A; Dos Santos, F...espandi
(2022). Track reconstruction and matching between emulsion and silicon pixel detectors for the SHiP-charm experiment [journal article - articolo]. In JOURNAL OF INSTRUMENTATION. Retrieved from https://hdl.handle.net/10446/288161
File allegato/i alla scheda:
File Dimensione del file Formato  
Ahdida_2022_J._Inst._17_P03013.pdf

accesso aperto

Versione: publisher's version - versione editoriale
Licenza: Creative commons
Dimensione del file 1.03 MB
Formato Adobe PDF
1.03 MB Adobe PDF Visualizza/Apri