Electrical machines (EMs) operated on high-voltage dc buses for contemporary transportation applications are significantly exposed to the risk of partial discharge (PD). The inception mechanism of PD is influenced by various factors, including pressure, temperature, and humidity. With the increasing interest in SiC-based inverters, the impact of rise time on PD has garnered significant attention. In this study, a comprehensive measurement of PD inception voltage (PDIV) is conducted using test voltages with five different rise time values under five relative humidity (RH) levels at 30 ◦C. The experimental results indicate that within the range of 30–200 ns, the rise time has minimal impact on PDIV, while voltage overshoot significantly affects PDIV in high-humidity environments.

(2025). Combined Effect of Short Rise Time and Relative Humidity on the Partial Discharge Inception Mechanism in Rotating Electrical Machines Insulation [journal article - articolo]. In IEEE TRANSACTIONS ON DIELECTRICS AND ELECTRICAL INSULATION. Retrieved from https://hdl.handle.net/10446/295145

Combined Effect of Short Rise Time and Relative Humidity on the Partial Discharge Inception Mechanism in Rotating Electrical Machines Insulation

Giangrande, Paolo;
2025-01-01

Abstract

Electrical machines (EMs) operated on high-voltage dc buses for contemporary transportation applications are significantly exposed to the risk of partial discharge (PD). The inception mechanism of PD is influenced by various factors, including pressure, temperature, and humidity. With the increasing interest in SiC-based inverters, the impact of rise time on PD has garnered significant attention. In this study, a comprehensive measurement of PD inception voltage (PDIV) is conducted using test voltages with five different rise time values under five relative humidity (RH) levels at 30 ◦C. The experimental results indicate that within the range of 30–200 ns, the rise time has minimal impact on PDIV, while voltage overshoot significantly affects PDIV in high-humidity environments.
articolo
2025
Ji, Y.; Giangrande, Paolo; Zhao, W.; Buticchi, G.; Zhang, P.
(2025). Combined Effect of Short Rise Time and Relative Humidity on the Partial Discharge Inception Mechanism in Rotating Electrical Machines Insulation [journal article - articolo]. In IEEE TRANSACTIONS ON DIELECTRICS AND ELECTRICAL INSULATION. Retrieved from https://hdl.handle.net/10446/295145
File allegato/i alla scheda:
File Dimensione del file Formato  
J56.pdf

Solo gestori di archivio

Descrizione: Published Version
Versione: publisher's version - versione editoriale
Licenza: Licenza default Aisberg
Dimensione del file 7.35 MB
Formato Adobe PDF
7.35 MB Adobe PDF   Visualizza/Apri
Pubblicazioni consigliate

Aisberg ©2008 Servizi bibliotecari, Università degli studi di Bergamo | Terms of use/Condizioni di utilizzo

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/10446/295145
Citazioni
  • Scopus 1
  • ???jsp.display-item.citation.isi??? ND
social impact