Precast industrial structures built in Italy in the postwar period until the 1980s were disadvantaged by the late seismic classification of the area. Nowadays, many of these buildings are located in areas with medium-high seismic risk and therefore require seismic retrofit measures to improve their safety. In this article, the evolution of the seismic risk of a reference prefabricated building is analyzed, with particular attention to the contribution of the retrofit of the connections of the roof system to the global seismic risk. Three states of the building are considered: the as-is state, the locally strengthened structure, and the fully retrofitted structure. The effectiveness of the strengthening measures is evaluated by comparing the performance of the structure through nonlinear dynamic analyses in terms of the demand-capacity relationship associated with each vulnerability of the building
Gli edifici prefabbricati ad uso industriale costruiti in Italia dal dopoguerra agli anni '80 sono stati penalizzati dalla tardiva classificazione sismica del territorio. Oggigiorno, molti di questi edifici si trovano in zone con rischio sismico medio-alto, pertanto richiedono interventi di adeguamento sismico per migliorare la loro sicurezza. Questo articolo analizza l'evoluzione del rischio sismico di un edificio prefabbricato di riferimento, con particolare attenzione al contributo del rinforzo delle connessioni del sistema di copertura al rischio sismico globale. Si considerano tre stati della struttura: lo stato di fatto, la struttura rinforzata localmente e la struttura completamente rinforzata. L'efficacia degli interventi di rinforzo è valutata confrontando le prestazioni della struttura, mediante analisi dinamiche non lineari, in termini di rapporto domanda/capacità associato a ciascuna vulnerabilità dell'edificio
(2024). Evolution of the seismic risk of a single-storey precast building as a function of the retrofit = Evoluzione del rischio sismico di un edificio prefabbricato monopiano al variare degli interventi di rinforzo . Retrieved from https://hdl.handle.net/10446/297225
Evolution of the seismic risk of a single-storey precast building as a function of the retrofit = Evoluzione del rischio sismico di un edificio prefabbricato monopiano al variare degli interventi di rinforzo
Minkada Eteme, Marius;Bosio, Marco;Belleri, Andrea;Riva, Paolo
2024-01-01
Abstract
Precast industrial structures built in Italy in the postwar period until the 1980s were disadvantaged by the late seismic classification of the area. Nowadays, many of these buildings are located in areas with medium-high seismic risk and therefore require seismic retrofit measures to improve their safety. In this article, the evolution of the seismic risk of a reference prefabricated building is analyzed, with particular attention to the contribution of the retrofit of the connections of the roof system to the global seismic risk. Three states of the building are considered: the as-is state, the locally strengthened structure, and the fully retrofitted structure. The effectiveness of the strengthening measures is evaluated by comparing the performance of the structure through nonlinear dynamic analyses in terms of the demand-capacity relationship associated with each vulnerability of the buildingFile | Dimensione del file | Formato | |
---|---|---|---|
ICC24 - Precast .pdf
Solo gestori di archivio
Versione:
publisher's version - versione editoriale
Licenza:
Licenza default Aisberg
Dimensione del file
1.61 MB
Formato
Adobe PDF
|
1.61 MB | Adobe PDF | Visualizza/Apri |
Pubblicazioni consigliate
Aisberg ©2008 Servizi bibliotecari, Università degli studi di Bergamo | Terms of use/Condizioni di utilizzo