Many industrial buildings built in Italy until the 1980s and designed to non-seismic standards are located in areas of moderate seismic risk and need to be retrofitted to increase their seismic safety. The Italian technical standards provide the criteria for interventions and indications for the quantitative assessment of the seismic risk. They allow different levels of risk reduction through local, ameliorative and fully compliant interventions, and in all cases the safety assessment of the whole structure is mandatory. However, in the case of a global intervention, the codes do not require an assessment of the impact of the retrofit on the local response, i.e. on the connections between different structural and non-structural elements. The aim of this paper is to perform an analysis of the evolution of the seismic risk of a reference industrial building made of precast elements. Three different states of the structure are considered: the as-built state, the locally strengthened structure and the fully strengthened structure are studied. The impact of the retrofitting measures is verified by comparing the performance of the structure using a multi-stripe analysis in terms of the demand/capacity ratio associated with each vulnerability of the structural and non-structural system.

(2024). Consideration on the development of the seismic risk of an existing precast building after retrofot interventions . In PROCEEDINGS - WORLD CONFERENCE ON EARTHQUAKE ENGINEERING. Retrieved from https://hdl.handle.net/10446/297289

Consideration on the development of the seismic risk of an existing precast building after retrofot interventions

Minkada Eteme, Marius;Belleri, Andrea;Bosio, Marco;Riva, Paolo;Labò, Simone
2024-01-01

Abstract

Many industrial buildings built in Italy until the 1980s and designed to non-seismic standards are located in areas of moderate seismic risk and need to be retrofitted to increase their seismic safety. The Italian technical standards provide the criteria for interventions and indications for the quantitative assessment of the seismic risk. They allow different levels of risk reduction through local, ameliorative and fully compliant interventions, and in all cases the safety assessment of the whole structure is mandatory. However, in the case of a global intervention, the codes do not require an assessment of the impact of the retrofit on the local response, i.e. on the connections between different structural and non-structural elements. The aim of this paper is to perform an analysis of the evolution of the seismic risk of a reference industrial building made of precast elements. Three different states of the structure are considered: the as-built state, the locally strengthened structure and the fully strengthened structure are studied. The impact of the retrofitting measures is verified by comparing the performance of the structure using a multi-stripe analysis in terms of the demand/capacity ratio associated with each vulnerability of the structural and non-structural system.
2024
ETEME MINKADA, Marius; Belleri, Andrea; Bosio, Marco; Riva, Paolo; Labo', Simone
File allegato/i alla scheda:
File Dimensione del file Formato  
WCEE2024-Minkada_etal.pdf

accesso aperto

Versione: publisher's version - versione editoriale
Licenza: Licenza Free to read
Dimensione del file 1.06 MB
Formato Adobe PDF
1.06 MB Adobe PDF Visualizza/Apri
Pubblicazioni consigliate

Aisberg ©2008 Servizi bibliotecari, Università degli studi di Bergamo | Terms of use/Condizioni di utilizzo

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/10446/297289
Citazioni
  • Scopus ND
  • ???jsp.display-item.citation.isi??? ND
social impact