Switched reluctance motors (SRMs) are suitable for drive systems with increased reliability. They are very tolerant of one of the most dangerous faults for any kind of electric machine, which is the windings partial inter-turn short circuit condition. FFT analysis of the source current can be used to diagnose the fault occurring in the SRM. In this paper it is shown that a partially shorted winding causes the appearance of diagnostic frequencies in the source current. The amplitudes of the diagnostic frequencies depend on the number of shorted coil turns. At the same time, the location of the fault has virtually no effect on the motor diagnostics.

(2025). The Impact of Inter-Turn Short Circuit Location Change on the Diagnostics Efficiency of a Multipole Switched Reluctance Motors . Retrieved from https://hdl.handle.net/10446/313988

The Impact of Inter-Turn Short Circuit Location Change on the Diagnostics Efficiency of a Multipole Switched Reluctance Motors

Minervini, Marcello
2025-01-01

Abstract

Switched reluctance motors (SRMs) are suitable for drive systems with increased reliability. They are very tolerant of one of the most dangerous faults for any kind of electric machine, which is the windings partial inter-turn short circuit condition. FFT analysis of the source current can be used to diagnose the fault occurring in the SRM. In this paper it is shown that a partially shorted winding causes the appearance of diagnostic frequencies in the source current. The amplitudes of the diagnostic frequencies depend on the number of shorted coil turns. At the same time, the location of the fault has virtually no effect on the motor diagnostics.
2025
Inglese
Proceedings of the 15th International 2025 IEEE Symposium on Diagnostics for Electrical Machines, Power Electronics and Drives, SDEMPED 2025
979-8-3503-8820-6
362
367
online
United States
Piscataway
IEEE (Institute of Electrical and Electronics Engineers)
SDEMPED 2025: 15th International IEEE Symposium on Diagnostics for Electrical Machines, Power Electronics and Drives, Dallas, TX, USA, 24-27 August 2025
15th
Dallas, TX, USA
24-27 August 2025
internazionale
contributo
Settore IIND-08/A - Convertitori, macchine e azionamenti elettrici
diagnostics; fault tolerant; intern-turn short circuit; multipole; switched reluctance motors
info:eu-repo/semantics/conferenceObject
5
Korkosz, Mariusz; Prokop, Jan; Bogusz, Piotr; Zasowski, Piotr; Minervini, Marcello
1.4 Contributi in atti di convegno - Contributions in conference proceedings::1.4.01 Contributi in atti di convegno - Conference presentations
reserved
Non definito
273
(2025). The Impact of Inter-Turn Short Circuit Location Change on the Diagnostics Efficiency of a Multipole Switched Reluctance Motors . Retrieved from https://hdl.handle.net/10446/313988
File allegato/i alla scheda:
File Dimensione del file Formato  
The Impact of Inter-Turn_ Minervini.pdf

Solo gestori di archivio

Versione: publisher's version - versione editoriale
Licenza: Licenza default Aisberg
Dimensione del file 1.85 MB
Formato Adobe PDF
1.85 MB Adobe PDF   Visualizza/Apri
Pubblicazioni consigliate

Aisberg ©2008 Servizi bibliotecari, Università degli studi di Bergamo | Terms of use/Condizioni di utilizzo

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/10446/313988
Citazioni
  • Scopus 0
  • ???jsp.display-item.citation.isi??? 0
social impact