Background: Transcatheter aortic valve implantation (TAVI) is a widely adopted, minimally invasive alternative to surgical aortic valve replacement. Despite its clinical success, TAVI can induce hemodynamic complications, which can be investigated using computational fluid dynamics (CFD). In this study, CFD was applied to evaluate the hemodynamic impact of catheter insertion during the TAVI procedure. Methods: CFD simulations were conducted in SimVascular to assess blood flow alterations at different stages of catheter insertion, from the iliac access to the ascending aorta, focusing on four critical phases of catheter advancement. Hemodynamic parameters were systematically analyzed across all simulated models. Results: Catheter insertion induced a pronounced local pressure drop and elevated wall shear stress (WSS) at the access-side iliac artery. Outlet flow analysis showed redistribution across branches, with reduced flow on the access side and compensatory increases in the contralateral femoral artery and the other branches. Oscillatory shear index (OSI) and turbulent kinetic energy (TKE) were reduced at the access site, whereas higher OSI and TKE were observed in the contralateral iliac artery. Local hemodynamics and WSS near the catheter tip were found to be sensitive to the catheter’s longitudinal position. Conclusion: This proof-of-concept study demonstrates that CFD can effectively capture catheter-induced hemodynamic disturbances during TAVI delivery, providing a foundation for patient-specific risk assessment and procedural optimization.

(2026). Computational fluid dynamics assessment of hemodynamic effects of catheter navigation during transcatheter aortic valve implantation [journal article - articolo]. In INTERNATIONAL JOURNAL OF ARTIFICIAL ORGANS. Retrieved from https://hdl.handle.net/10446/335466

Computational fluid dynamics assessment of hemodynamic effects of catheter navigation during transcatheter aortic valve implantation

Soliveri, Luca;Lanzarone, Ettore;Massa, Francesco Carlo
2026-09-24

Abstract

Background: Transcatheter aortic valve implantation (TAVI) is a widely adopted, minimally invasive alternative to surgical aortic valve replacement. Despite its clinical success, TAVI can induce hemodynamic complications, which can be investigated using computational fluid dynamics (CFD). In this study, CFD was applied to evaluate the hemodynamic impact of catheter insertion during the TAVI procedure. Methods: CFD simulations were conducted in SimVascular to assess blood flow alterations at different stages of catheter insertion, from the iliac access to the ascending aorta, focusing on four critical phases of catheter advancement. Hemodynamic parameters were systematically analyzed across all simulated models. Results: Catheter insertion induced a pronounced local pressure drop and elevated wall shear stress (WSS) at the access-side iliac artery. Outlet flow analysis showed redistribution across branches, with reduced flow on the access side and compensatory increases in the contralateral femoral artery and the other branches. Oscillatory shear index (OSI) and turbulent kinetic energy (TKE) were reduced at the access site, whereas higher OSI and TKE were observed in the contralateral iliac artery. Local hemodynamics and WSS near the catheter tip were found to be sensitive to the catheter’s longitudinal position. Conclusion: This proof-of-concept study demonstrates that CFD can effectively capture catheter-induced hemodynamic disturbances during TAVI delivery, providing a foundation for patient-specific risk assessment and procedural optimization.
articolo
24-set-2026
Grassi, Matteo; Mazzocchi, Alessandro; Vezzoli, Nicola; Soliveri, Luca; Lanzarone, Ettore; Massa, Francesco Carlo
(2026). Computational fluid dynamics assessment of hemodynamic effects of catheter navigation during transcatheter aortic valve implantation [journal article - articolo]. In INTERNATIONAL JOURNAL OF ARTIFICIAL ORGANS. Retrieved from https://hdl.handle.net/10446/335466
File allegato/i alla scheda:
File Dimensione del file Formato  
grassi-et-al-2026-computational-fluid-dynamics-assessment-of-hemodynamic-effects-of-catheter-navigation-during.pdf

Solo gestori di archivio

Versione: publisher's version - versione editoriale
Licenza: Licenza default Aisberg
Dimensione del file 2.07 MB
Formato Adobe PDF
2.07 MB Adobe PDF   Visualizza/Apri
Pubblicazioni consigliate

Aisberg ©2008 Servizi bibliotecari, Università degli studi di Bergamo | Terms of use/Condizioni di utilizzo

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/10446/335466
Citazioni
  • Scopus ND
  • ???jsp.display-item.citation.isi??? ND
social impact