Medical device software malfunctioning can lead to injuries or death for humans and, therefore, its development should adhere to certification standards. However, these standards establish general guidelines on the use of common software engineering activities without any indication regarding methods and techniques to assure safety and reliability. This paper presents a formal development process, based on the Abstract State Machine method, that integrates most of the activities required by the standards. The process permits to obtain, through a sequence of refinements, more detailed models that can be formally validated and verified. Offline and online testing techniques permit to check the conformance of the implementation w.r.t. the specification. The process is applied to the validation of the SAM medical software, that is used to measure the patients' stereoacuity in the diagnosis of amblyopia.
(2015). Formal validation and verification of a medical software critical component [conference presentation - intervento a convegno]. Retrieved from http://hdl.handle.net/10446/50079
Formal validation and verification of a medical software critical component
Bonfanti, Silvia;Gargantini, Angelo Michele;
2015-01-01
Abstract
Medical device software malfunctioning can lead to injuries or death for humans and, therefore, its development should adhere to certification standards. However, these standards establish general guidelines on the use of common software engineering activities without any indication regarding methods and techniques to assure safety and reliability. This paper presents a formal development process, based on the Abstract State Machine method, that integrates most of the activities required by the standards. The process permits to obtain, through a sequence of refinements, more detailed models that can be formally validated and verified. Offline and online testing techniques permit to check the conformance of the implementation w.r.t. the specification. The process is applied to the validation of the SAM medical software, that is used to measure the patients' stereoacuity in the diagnosis of amblyopia.File | Dimensione del file | Formato | |
---|---|---|---|
15.pdf
Solo gestori di archivio
Versione:
publisher's version - versione editoriale
Licenza:
Licenza default Aisberg
Dimensione del file
782.97 kB
Formato
Adobe PDF
|
782.97 kB | Adobe PDF | Visualizza/Apri |
Pubblicazioni consigliate
Aisberg ©2008 Servizi bibliotecari, Università degli studi di Bergamo | Terms of use/Condizioni di utilizzo