Reinforcement corrosion can induce sev- ere damage in reinforced concrete (RC) columns leading to a relevant loss of bearing capacity. This condition can be even more critical in case of seismic events. The possibility of repairing and strengthening corrosion damaged columns with high performance fiber RC (HPFRC) jacketing is investigated herein. The main aim of the retrofit intervention is, not only to restore the original bearing capacity, but also to increase the column durability. In order to investigate the effectiveness of the proposed technique, full-scale tests on RC columns under cyclic loads have been performed. Two columns were artificially corroded and one of them was repaired with a HPFRC jacket. The obtained results are compared with those mea- sured on a third un-corroded RC column.

(2016). Corroded RC columns repair and strengthening with high performance fiber reinforced concrete jacket [journal article - articolo]. In MATERIALS AND STRUCTURES. Retrieved from http://hdl.handle.net/10446/56184

Corroded RC columns repair and strengthening with high performance fiber reinforced concrete jacket

MOSTOSI, Serena;RIVA, Paolo
2016-01-01

Abstract

Reinforcement corrosion can induce sev- ere damage in reinforced concrete (RC) columns leading to a relevant loss of bearing capacity. This condition can be even more critical in case of seismic events. The possibility of repairing and strengthening corrosion damaged columns with high performance fiber RC (HPFRC) jacketing is investigated herein. The main aim of the retrofit intervention is, not only to restore the original bearing capacity, but also to increase the column durability. In order to investigate the effectiveness of the proposed technique, full-scale tests on RC columns under cyclic loads have been performed. Two columns were artificially corroded and one of them was repaired with a HPFRC jacket. The obtained results are compared with those mea- sured on a third un-corroded RC column.
articolo
2016
Meda, Alberto; Mostosi, Serena; Rinaldi, Zila; Riva, Paolo
(2016). Corroded RC columns repair and strengthening with high performance fiber reinforced concrete jacket [journal article - articolo]. In MATERIALS AND STRUCTURES. Retrieved from http://hdl.handle.net/10446/56184
File allegato/i alla scheda:
File Dimensione del file Formato  
Corroded RC columns repairs.pdf

Solo gestori di archivio

Versione: publisher's version - versione editoriale
Licenza: Licenza default Aisberg
Dimensione del file 3.28 MB
Formato Adobe PDF
3.28 MB Adobe PDF   Visualizza/Apri
RivaPaolo1_compressed.pdf

Open Access dal 13/05/2016

Descrizione: This is a post-peer-review, pre-copyedit version of an article published in MATERIALS AND STRUCTURES. The final authenticated version is available online at: 10.1617/s11527-015-0627-1
Versione: postprint - versione referata/accettata senza referaggio
Licenza: Licenza default Aisberg
Dimensione del file 1.49 MB
Formato Adobe PDF
1.49 MB Adobe PDF Visualizza/Apri
Pubblicazioni consigliate

Aisberg ©2008 Servizi bibliotecari, Università degli studi di Bergamo | Terms of use/Condizioni di utilizzo

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/10446/56184
Citazioni
  • Scopus 111
  • ???jsp.display-item.citation.isi??? 93
social impact