In this paper, the modifications induced by the presence of an inlet flow non uniformity on the aerodynamic performance of a nozzle vane cascade are experimentally assessed. Tests were carried out in a six vane linear cascade whose profile is typical of a first stage nozzle guide vane of a modern heavy duty gas turbine. An obstruction was located in the wind tunnel inlet section to produce a non uniform flow upstream of the leading edge plane. The cascade was tested in an atmospheric wind tunnel at an inlet Mach number Ma1 = 0.12, with a high turbulence intensity (Tu1 = 9%) and variable obstruction tangential and axial positions, as well as tangential extension. The presented results show that an inlet flow non uniformity influences the stagnation point position when it faces the vane leading edge from the suction side. A relevant increase of both 2D and secondary losses are observed when the non uniformity is aligned to the vane leading edge. When it is instead located in between the passage it does not affect the stagnation point location, in the meanwhile allowing a reduction in the secondary loss.

Aerothermal Performance of a Nozzle Vane Cascade with a Generic Non Uniform Inlet Flow Condition - Part I: Influence of Non Uniformity Location

PERDICHIZZI, Antonio Giovanni;ABDEH, Hamed;BARIGOZZI, Giovanna;
2017-01-01

Abstract

In this paper, the modifications induced by the presence of an inlet flow non uniformity on the aerodynamic performance of a nozzle vane cascade are experimentally assessed. Tests were carried out in a six vane linear cascade whose profile is typical of a first stage nozzle guide vane of a modern heavy duty gas turbine. An obstruction was located in the wind tunnel inlet section to produce a non uniform flow upstream of the leading edge plane. The cascade was tested in an atmospheric wind tunnel at an inlet Mach number Ma1 = 0.12, with a high turbulence intensity (Tu1 = 9%) and variable obstruction tangential and axial positions, as well as tangential extension. The presented results show that an inlet flow non uniformity influences the stagnation point position when it faces the vane leading edge from the suction side. A relevant increase of both 2D and secondary losses are observed when the non uniformity is aligned to the vane leading edge. When it is instead located in between the passage it does not affect the stagnation point location, in the meanwhile allowing a reduction in the secondary loss.
2017
Perdichizzi, Antonio Giovanni; Abdeh, Hamed; Barigozzi, Giovanna; Henze, M.; Krueckels, J.
File allegato/i alla scheda:
File Dimensione del file Formato  
turbo_139_03_031002 (1).pdf

Solo gestori di archivio

Versione: publisher's version - versione editoriale
Licenza: Licenza default Aisberg
Dimensione del file 4.17 MB
Formato Adobe PDF
4.17 MB Adobe PDF   Visualizza/Apri
Pubblicazioni consigliate

Aisberg ©2008 Servizi bibliotecari, Università degli studi di Bergamo | Terms of use/Condizioni di utilizzo

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/10446/85811
Citazioni
  • Scopus 12
  • ???jsp.display-item.citation.isi??? 7
social impact