In this work, the use of continuous time charge amplification and shaping is proposed for processing the signal delivered by CMOS pixel sensors in charged particle tracking applications. Such a choice aims at exploiting the large scale of integration of modern deep submicron CMOS technologies to incorporate both the potential for thin detector fabrication, inherent in the concept of monolithic active pixel sensors (MAPS), and the data sparsification capabilities featured by hybrid pixels into the design of a single device. With respect to classical MAPS, adoption of the above readout method involves a substantial change in the guidelines for the design of the front-end electronics and of the whole elementary cell, in order not to jeopardize the collection efficiency of the sensitive electrode. For the purpose of supporting the feasibility of the proposed solution, the paper discusses some experimental results relevant to monolithic CMOS sensor prototypes, fabricated in a 0.13 μm technology, which were designed according to the mentioned rules. ©2005 IEEE.

(2005). Non-standard approach to charge signal processing in CMOS MAPS for charged particle trackers . Retrieved from http://hdl.handle.net/10446/86497

Non-standard approach to charge signal processing in CMOS MAPS for charged particle trackers

MANGHISONI, Massimo;RE, Valerio;TRAVERSI, Gianluca
2005-01-01

Abstract

In this work, the use of continuous time charge amplification and shaping is proposed for processing the signal delivered by CMOS pixel sensors in charged particle tracking applications. Such a choice aims at exploiting the large scale of integration of modern deep submicron CMOS technologies to incorporate both the potential for thin detector fabrication, inherent in the concept of monolithic active pixel sensors (MAPS), and the data sparsification capabilities featured by hybrid pixels into the design of a single device. With respect to classical MAPS, adoption of the above readout method involves a substantial change in the guidelines for the design of the front-end electronics and of the whole elementary cell, in order not to jeopardize the collection efficiency of the sensitive electrode. For the purpose of supporting the feasibility of the proposed solution, the paper discusses some experimental results relevant to monolithic CMOS sensor prototypes, fabricated in a 0.13 μm technology, which were designed according to the mentioned rules. ©2005 IEEE.
2005
Inglese
2005 IEEE Nuclear Science Symposium Conference Record
9780780392212
2
969
973
online
file su supporto
IEEE
2005 IEEE Nuclear Science Symposium
Fajardo, Puerto Rico
23 - 29 October 2005
IEEE
internazionale
contributo
Settore ING-INF/01 - Elettronica
CMOS front-end circuits; Low-noise electronics; Monolithic active pixel sensors; Radiation; Nuclear and High Energy Physics; Radiology, Nuclear Medicine and Imaging
info:eu-repo/semantics/conferenceObject
5
Ratti, Lodovico; Manghisoni, Massimo; Re, Valerio; Speziali, Valeria; Traversi, Gianluca
1.4 Contributi in atti di convegno - Contributions in conference proceedings::1.4.01 Contributi in atti di convegno - Conference presentations
reserved
Non definito
273
(2005). Non-standard approach to charge signal processing in CMOS MAPS for charged particle trackers . Retrieved from http://hdl.handle.net/10446/86497
File allegato/i alla scheda:
File Dimensione del file Formato  
01596415.pdf

Solo gestori di archivio

Versione: publisher's version - versione editoriale
Licenza: Licenza default Aisberg
Dimensione del file 291.84 kB
Formato Adobe PDF
291.84 kB Adobe PDF   Visualizza/Apri
Pubblicazioni consigliate

Aisberg ©2008 Servizi bibliotecari, Università degli studi di Bergamo | Terms of use/Condizioni di utilizzo

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/10446/86497
Citazioni
  • Scopus 7
  • ???jsp.display-item.citation.isi??? 6
social impact