This paper describes the calibration procedure for the drift tubes of the CMS barrel muon system and reports the main results obtained with data collected during a high statistics cosmic ray data-taking period. The main goal of the calibration is to determine, for each drift cell, the minimum time delay for signals relative to the trigger, accounting for the drift velocity within the cell. The accuracy of the calibration procedure is influenced by the random arrival time of the cosmic muons relative to the LHC clock cycle. A more refined analysis of the drift velocity was performed during the offline reconstruction phase, which takes into account this feature of cosmic ray events.

(2010). Calibration of the CMS drift tube chambers and measurement of the drift velocity with cosmic rays [journal article - articolo]. In JOURNAL OF INSTRUMENTATION. Retrieved from http://hdl.handle.net/10446/187104

Calibration of the CMS drift tube chambers and measurement of the drift velocity with cosmic rays

S. Mattiazzo;
2010-01-01

Abstract

This paper describes the calibration procedure for the drift tubes of the CMS barrel muon system and reports the main results obtained with data collected during a high statistics cosmic ray data-taking period. The main goal of the calibration is to determine, for each drift cell, the minimum time delay for signals relative to the trigger, accounting for the drift velocity within the cell. The accuracy of the calibration procedure is influenced by the random arrival time of the cosmic muons relative to the LHC clock cycle. A more refined analysis of the drift velocity was performed during the offline reconstruction phase, which takes into account this feature of cosmic ray events.
articolo
2010
Chatrchyan, S.; Khachatryan, V.; Sirunyan, A. M.; Adam, W.; Arnold, B.; Bergauer, H.; Bergauer, T.; Dragicevic, M.; Eichberger, M.; Ero, J.; Friedl, M...espandi
(2010). Calibration of the CMS drift tube chambers and measurement of the drift velocity with cosmic rays [journal article - articolo]. In JOURNAL OF INSTRUMENTATION. Retrieved from http://hdl.handle.net/10446/187104
File allegato/i alla scheda:
File Dimensione del file Formato  
CMS_Collaboration_2010_J._Inst._5_T03016.pdf

Solo gestori di archivio

Versione: publisher's version - versione editoriale
Licenza: Licenza default Aisberg
Dimensione del file 1.69 MB
Formato Adobe PDF
1.69 MB Adobe PDF   Visualizza/Apri
Pubblicazioni consigliate

Aisberg ©2008 Servizi bibliotecari, Università degli studi di Bergamo | Terms of use/Condizioni di utilizzo

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/10446/187104
Citazioni
  • Scopus 41
  • ???jsp.display-item.citation.isi??? 40
social impact