We present a loosely coupled scheme for the numerical simulation of the cardiac electro- fluid-structure interaction problem, whose solution is typically computationally intensive due to the need to suitably treat the coupling of the different submodels. Our scheme relies on a segregated treatment of the subproblems, in particular on an explicit Robin-Neumann algorithm for the fluid-structure interaction, aiming at reducing the computational burden of numerical simulations. The results, both in an ideal and a realistic cardiac setting, show that the proposed scheme is stable at the regimes typical of cardiac simulations. From a comparison with a scheme with implicit fluid-structure interaction, it emerges that, while conservation properties are not fully preserved, computational times significantly benefit from the explicit scheme. Overall, the explicit discretization represents a good trade-off between accuracy and cost, and is a valuable alternative to implicit schemes for fast large- scale simulations.

(2023). A stable loosely-coupled scheme for cardiac electro-fluid-structure interaction [journal article - articolo]. In JOURNAL OF COMPUTATIONAL PHYSICS. Retrieved from https://hdl.handle.net/10446/247769

A stable loosely-coupled scheme for cardiac electro-fluid-structure interaction

Gigante, Giacomo;Vergara, Christian
2023-01-01

Abstract

We present a loosely coupled scheme for the numerical simulation of the cardiac electro- fluid-structure interaction problem, whose solution is typically computationally intensive due to the need to suitably treat the coupling of the different submodels. Our scheme relies on a segregated treatment of the subproblems, in particular on an explicit Robin-Neumann algorithm for the fluid-structure interaction, aiming at reducing the computational burden of numerical simulations. The results, both in an ideal and a realistic cardiac setting, show that the proposed scheme is stable at the regimes typical of cardiac simulations. From a comparison with a scheme with implicit fluid-structure interaction, it emerges that, while conservation properties are not fully preserved, computational times significantly benefit from the explicit scheme. Overall, the explicit discretization represents a good trade-off between accuracy and cost, and is a valuable alternative to implicit schemes for fast large- scale simulations.
michele.bucelli@polimi.it
articolo
2023
Inglese
cartaceo
online
490
art. 112326
1
24
esperti anonimi
Settore MAT/08 - Analisi Numerica
Settore MAT/05 - Analisi Matematica
Cardiac modeling; Multiphysics; Electromechanics; Fluid-structure interaction; Robin-Neumann interface conditions
indice consultabile alla pagina https://www.sciencedirect.com/journal/journal-of-computational-physics/vol/490/suppl/C
Bucelli, Michele; Gabriel, Martin Geraint; Quarteroni, Alfio; Gigante, Giacomo; Vergara, Christian
info:eu-repo/semantics/article
open
(2023). A stable loosely-coupled scheme for cardiac electro-fluid-structure interaction [journal article - articolo]. In JOURNAL OF COMPUTATIONAL PHYSICS. Retrieved from https://hdl.handle.net/10446/247769
Non definito
5
1.1 Contributi in rivista - Journal contributions::1.1.01 Articoli/Saggi in rivista - Journal Articles/Essays
262
File allegato/i alla scheda:
File Dimensione del file Formato  
1-s2.0-S0021999123004217-main.pdf

accesso aperto

Versione: publisher's version - versione editoriale
Licenza: Creative commons
Dimensione del file 2.92 MB
Formato Adobe PDF
2.92 MB Adobe PDF Visualizza/Apri
Pubblicazioni consigliate

Aisberg ©2008 Servizi bibliotecari, Università degli studi di Bergamo | Terms of use/Condizioni di utilizzo

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/10446/247769
Citazioni
  • Scopus 13
  • ???jsp.display-item.citation.isi??? 12
social impact