The evaluation of the state of preservation and of the consequent residual capacity of existing structures is a major issue nowadays, especially in the field of infrastructures, due to recent collapses and to the economic costs and social impacts of the maintenance works. In reinforced concrete bridges, a critical aspect is the identification and measurement of the actual damage condition, and the calibration of the parameters to be implemented in structural analyses. This paper presents the preliminary results of the on-site survey and material characterization of a degraded side beam of one of the first example of Maillart bridges in Italy, built in 1912 in the province of Bergamo. Preliminary considerations on the residual capacity of the degraded side beam were drawn and compared to the actual load demand.
(2023). Preliminary structural assessment of a corroded RC beam in a Maillart bridge . Retrieved from https://hdl.handle.net/10446/259669
Preliminary structural assessment of a corroded RC beam in a Maillart bridge
Castelli, Simone;Belleri, Andrea;Persico, Michele;Rota, Luca;Riva, Paolo;Azzola, Pietro;Cardaci, Alessio
2023-01-01
Abstract
The evaluation of the state of preservation and of the consequent residual capacity of existing structures is a major issue nowadays, especially in the field of infrastructures, due to recent collapses and to the economic costs and social impacts of the maintenance works. In reinforced concrete bridges, a critical aspect is the identification and measurement of the actual damage condition, and the calibration of the parameters to be implemented in structural analyses. This paper presents the preliminary results of the on-site survey and material characterization of a degraded side beam of one of the first example of Maillart bridges in Italy, built in 1912 in the province of Bergamo. Preliminary considerations on the residual capacity of the degraded side beam were drawn and compared to the actual load demand.File | Dimensione del file | Formato | |
---|---|---|---|
Preliminary structural assessment of a corroded RC beam in a Maillart bridge.pdf
Solo gestori di archivio
Versione:
publisher's version - versione editoriale
Licenza:
Licenza default Aisberg
Dimensione del file
440.63 kB
Formato
Adobe PDF
|
440.63 kB | Adobe PDF | Visualizza/Apri |
FIBPRO-0063-2023-E_cover.pdf
Solo gestori di archivio
Versione:
cover/index - copertina/indice
Licenza:
Licenza default Aisberg
Dimensione del file
30.45 kB
Formato
Adobe PDF
|
30.45 kB | Adobe PDF | Visualizza/Apri |
Pubblicazioni consigliate
Aisberg ©2008 Servizi bibliotecari, Università degli studi di Bergamo | Terms of use/Condizioni di utilizzo