The aim of this work is to investigate the performance of closed-loop impedance control in the case of a kinesthetic interface, more precisely to propose this control approach even for devices in which the natural dynamics of the system are relevant. This characteristic can be found in an industrial scenario where commercial components are generally used; hence the system can't be optimized as conversely occurs in a laboratory/ research environment where custom components are generally developed. It is shown that it is possible to guarantee a high dynamic accuracy using the closed-loop impedance control with force feedback and model feedforward. Therefore this approach is suggested as a valid alternative of the most diffused admittance control. The device implemented for the tests and the obtained results are described below.
(2014). Control system design of 1 DOF kinesthetic interface [conference presentation - intervento a convegno]. Retrieved from http://hdl.handle.net/10446/31985
Control system design of 1 DOF kinesthetic interface
RIGHETTINI, Paolo;GOTTI, Alessandro;ROSSETTI, Mattia;STRADA, Roberto
2014-01-01
Abstract
The aim of this work is to investigate the performance of closed-loop impedance control in the case of a kinesthetic interface, more precisely to propose this control approach even for devices in which the natural dynamics of the system are relevant. This characteristic can be found in an industrial scenario where commercial components are generally used; hence the system can't be optimized as conversely occurs in a laboratory/ research environment where custom components are generally developed. It is shown that it is possible to guarantee a high dynamic accuracy using the closed-loop impedance control with force feedback and model feedforward. Therefore this approach is suggested as a valid alternative of the most diffused admittance control. The device implemented for the tests and the obtained results are described below.File | Dimensione del file | Formato | |
---|---|---|---|
(T2) Control system design of 1 DOF kinesthetic interface.pdf
Solo gestori di archivio
Descrizione: publisher's version - versione dell'editore
Dimensione del file
283.76 kB
Formato
Adobe PDF
|
283.76 kB | Adobe PDF | Visualizza/Apri |
Pubblicazioni consigliate
Aisberg ©2008 Servizi bibliotecari, Università degli studi di Bergamo | Terms of use/Condizioni di utilizzo